Fault level
Fault levelThree-phase symmetrical fault current I″k (IEC 60909)Fault levelNetwork feeder (source) impedance from fault levelFault levelTransformer impedance and IEC 60909 correction factor KTFault levelFault current at the end of a cable or overhead lineFault levelMVA method: source plus transformer plus local infeedFault levelLV-side fault through a transformer and the current seen on the HV sideFault levelX/R, R and X from fault level and impedance angle
Asymmetry and duration
Unbalanced faults
Per-unit
HV cables
HV cablesElectric stress in a screened single-core cableHV cablesOptimum conductor radius for minimum stress (Ri/rc = e)HV cablesCapacitance of a screened cable (IEC 60287-1-1)HV cablesCable charging current and three-phase charging kvarHV cablesConductor a.c. resistance at operating temperature (IEC 60287-1-1)HV cablesInductance and reactance of single-core cables, trefoil and flatHV cablesThree-phase voltage drop of an HV cable
Insulation
Short-circuit rating
Sheath bonding
Testing
Overhead lines
Overhead linesLine inductance and reactance per phase (GMD/GMR)Overhead linesLine capacitance and charging current per phaseOverhead linesSurge impedance and propagation velocityOverhead linesSurge impedance loading (SIL)Overhead linesFerranti voltage rise at the open receiving endOverhead linesShort line: sending-end voltage, regulation and lossesOverhead linesMedium line nominal-π: sending-end voltage and currentOverhead linesConductor sag: parabola and catenary
Transients and insulation
Transients and insulationTravelling wave reflection and transmission at a junctionTransients and insulationCorona: disruptive critical and visual inception voltage (Peek)Transients and insulationUniform-field air breakdown (Paschen, Kuffel, 3 kV/mm)Transients and insulationField between coaxial cylinders and utilisation factorTransients and insulationField between concentric spheres and utilisation factorTransients and insulationLightning-induced overvoltage on a line (Rusck, simplified)Transients and insulationAltitude correction factor for external insulation (IEC 60071-2)
Power quality and networks
Power quality and networksThree-phase power and line currentPower quality and networksCapacitor bank rating for power-factor correctionPower quality and networksCapacitor bank voltage rise and parallel resonancePower quality and networksMotor starting voltage dipPower quality and networksEmbedded generation voltage risePower quality and networksRate of change of frequency after a loss of infeed
Transformers
Protection
ProtectionIDMT relay operating time, IEC 60255-151 curvesProtectionInverse-time relay operating time, IEEE C37.112 curvesProtectionGrading margin check between two inverse-time relaysProtectionRequired grading margin from relay and CT errors (NPAG)ProtectionCT knee-point voltage requirementProtectionCT effective accuracy-limit factor with actual burdenProtectionNeutral earthing resistor value and rating
Substation earthing
Substation earthingEarth potential rise from earth fault current (split / reduction factor)Substation earthingHOT / COLD and high EPR site classification (ENA TS 41-24, EREC S34)Substation earthingSubstation grid resistance (Sverak, IEEE 80)Substation earthingTransferred potential to a remote point (hemispherical approximation)
Electrode resistance
Touch and step
Soil resistivity
Arc flash: IEEE 1584
Arc flash: other methods
Arc flash: other methodsIEEE 1584-2002 empirical model (superseded, for comparison with older studies)Arc flash: other methodsRalph Lee theoretical method (above 15 kV, or outside the empirical models)Arc flash: other methodsDoughty–Neal incident energy, 600 V and below (open air and 508 mm box)Arc flash: other methodsDC arc flash: maximum power method (Ammerman et al. / NFPA 70E Annex D)Arc flash: other methodsDC arc flash: Stokes & Oppenlander arc resistance (iterative arcing current)
Arc flash: risk and PPE
Arc flash: risk and PPEArc blast pressure at a distance (Lee 1987)Arc flash: risk and PPEArc flash boundary from a known incident energy and distance exponentArc flash: risk and PPEIncident energy at a different working distance or arc durationArc flash: risk and PPEIncident energy reduction from faster clearing or greater distance (maintenance switch, remote operation)Arc flash: risk and PPEStoll curve: second-degree burn threshold for an exposure timeArc flash: risk and PPEArc-rated PPE check: incident energy against garment arc rating and NFPA 70E categoriesArc flash: risk and PPEIEC 61482-1-2 box test class check (APC 1 / APC 2) by the DGUV 203-077 energy method