Plug and socket types, mains voltage and supply frequency for every country and territory, with sources and a confidence rating for each entry. Pick a plug type to see where it is used, or check what a UK appliance needs before you travel.

Plug types, voltage and frequency by country

Showing 236 of 236 countries and territories

Plugs and sockets

Types
Type C, Type F
Most common
Type C
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some references give 230 V; treat as 220-230 V.

Notes

Mix of unearthed Europlug-style outlets and Schuko-type outlets; supply quality varies widely outside Kabul.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older compilations give 220 V.

Notes

Schuko (F) is the usual earthed socket; the US government list shows only C. Pass 3: Upgraded: C/F compatibility corroborated (ANWB + WorldStandards); 230 V from WorldStandards/ITA (voltage not stated by ANWB). ADAC confirms 230 V 50 Hz.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)No adapter needed: Dutch (type C/F) plugs fit almost all sockets
  2. ADAC (German automobile club) - destination facts (opens in a new tab)230 V, 50 Hz; no adapter needed for German plugs
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V with some 127/220 V.

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type F, Type I
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Notes

US-style supply; some Australian/NZ-style outlets also found.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older compilations give 220 V.

Notes

Sources disagree on the earthed type (F vs E); check locally. Pass 3: Upgraded: C/F and 230 V agree across ANWB and WorldStandards.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; two-round-hole sockets, unearthed type C or earthed type F
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

Sources disagree on plug types. Pass 3: 50 Hz (±2%) verified from the supply regulation; voltage and plug types unverified. Check local rules.

Check local rules

Sources

  1. Angola - Presidential Decree 27/01 Electricity Supply Regulation (angolex) (opens in a new tab)Art. 5: supply at 50 Hz ±2%; LV voltage within ±10% of the contracted nominal
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
110 V
Frequency
60 Hz

Frequency: One older source lists 50 Hz.

Notes

Sources conflict: an older government list gives 230 V 50 Hz British type G, current sources give 110 V 60 Hz US-style. Check local rules.

Check local rules

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
60 Hz

Voltage: Some 110 V supplies also found.

Notes

Unusual 230 V at 60 Hz, but some 110 V outlets exist (notably hotels). Sources disagree on outlet types.

Corroborated

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

National standard is IRAM 2073 (type I, angled flat pins with earth) for class I appliances and IRAM 2063 two-pole plugs for class II; sockets on sale must be earthed IRAM 2071 outlets. Combined round/flat outlets were phased out (sale banned after 2007), but old round-pin type C outlets still exist in older buildings - carry a C adapter as backup. Pass 3: Correction: plug list reduced to I (legal standard; C kept in notes as legacy). Plug verified from the resolution; 220 V verified (IRAM 2071 scope 220-250 V); 50 Hz corroborated.

Corroborated

Sources

  1. Argentina.gob.ar - Resolución SICyM 524/1998 (socket-outlets and plugs, original text) (opens in a new tab)Socket-outlets up to 250 V 10/20 A must be two-pole with earth (IRAM 2071, for 220-250 V supply); earthed plugs must follow IRAM 2073, unearthed plugs IRAM 2063; mixed-geometry outlets allowed only until Feb 2000
  2. Ingeniería Eléctrica (Editores SRL) - Marco normativo de fichas y tomacorrientes (opens in a new tab)Summarises Res. 524/98, Res. 92/98 and Res. 9/2005 which ended sale of combined 'biuso' outlets
  3. VDE (German electrical engineering association and standards publisher) - power supply when travelling (opens in a new tab)Independent listing: Argentina 220 V, 50 Hz, type I only
  4. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 50 Hz, 220/380 V, C/I
  5. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, I

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older references list 220 V.

Notes

Former Soviet standard, now aligned with European 230/400 V; Schuko-type outlets common. Pass 3: Third independent listing (VDE) added.

Corroborated

Plugs and sockets

Types
Type A, Type B, Type F
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Voltage: Also quoted as 127 V.

Notes

US-style outlets; occasional Schuko-type.

Corroborated

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Formerly 240/415 V; supply often runs at 235-245 V.

Notes

AS/NZS 3112 type I outlets, usually individually switched. Nominal changed from 240/415 V to 230/400 V (AS 60038); measured voltage is often still near 240 V.

Verified

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard; two-pin Europlug (C) also fits. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older references list 220 V.

Notes

European-style round-pin outlets; older buildings may still have unearthed type C points.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Yes, earthed sockets are standard

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
208 V

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: 400/230 V +6%.

Frequency: 50 Hz ±2%.

Notes

13 A 3-pin (G) sockets; 15/16 A round-pin (D/M) sockets also permitted. Field confidence - plugs: verified, voltage: verified, frequency: verified.

Verified

Sources

  1. EWA Bahrain: EDD Regulation for Electricity Installations (opens in a new tab)400/230 V +6%, 50 Hz ±2%; socket outlets 13 A 3-pin or 15/16 A round-pin
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type G, Type K
Most common
Type D
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Some sources quote 230 V.

Notes

Wide mix of outlets; many sockets are 'universal' types accepting several plugs. Earthing of outlets is inconsistent. Pass 3: Frequency verified from the regulator's grid code; 220/230 V and the mixed plug list remain corroborated only.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
115 V
Frequency
50 Hz
Three-phase
200 V

Notes

Unusual 115 V at 50 Hz: US 60 Hz clocks and some motors may run slow or hot.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Nominal 230/400 V under GOST 29322-2014; many local documents and VDE still quote 220/380 V.

Notes

Soviet-era sockets without earth still common in older buildings. Field confidence - plugs: corroborated, voltage: corroborated, frequency: corroborated.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. VDE: Power supply and safety when travelling (opens in a new tab)Plug types, voltage and 50 Hz for listed European countries (German standards body)
  4. NormaCS expert answer on GOST 29322-2014 (opens in a new tab)GOST 29322-2014 (IEC 60038) 230/400 V mandatory in Customs Union states, though older documents still cite 220/380 V
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

French-style pin-earth sockets (E); Schuko-hybrid plugs (E/F) fit. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type G
Most common
Type B
Earthed
Not recorded

Supply

Voltage
110 V / 220 V
Frequency
60 Hz

Notes

Both 110 V US-style and 220 V outlets exist.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Sources disagree (E vs D). Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Yes, earthed sockets are standard

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
208 V

Notes

North American-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type D, Type F, Type G, Type M
Most common
Type D
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Indian-style type D/M outlets are common alongside European types. Only one secondary source could be checked. Pass 3: 230/400 V verified from the regulator; plug types still single-source. Check local rules.

Check local rules

Sources

  1. Electricity Regulatory Authority of Bhutan - Internal House Wiring Rules and Regulations 2025 (opens in a new tab)Low voltage defined as 230 V phase-neutral single-phase, 400 V phase-phase three-phase; plug/socket standards per BTS 272:2019
  2. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, C/D/M

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type C
Most common
Type C
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz

Voltage: Older data lists 110/220 V systems.

Notes

Mostly 230 V, but some older 115 V supplies have been reported in parts of La Paz; check before use.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older compilations give 220 V.

Notes

Sources disagree on the earthed type (F vs E); F is generally reported. Pass 3: Upgraded: C/F corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)No adapter needed: Dutch (type C/F) plugs fit almost all sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type D, Type G, Type M
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220-231 V.

Notes

Most outlets are type G (BS 1363) or type D; South African-style type M also occurs. Sources disagree on the dominant type, so carry adapters for G and M. Pass 3: Correction: plug list widened from M only to D/G/M; 230 V corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; most sockets type G or type D; type M also occurs
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type N
Most common
Type N
Earthed
Yes, earthed sockets are standard

Supply

Voltage
127 V / 220 V
Frequency
60 Hz
Three-phase
220 V / 380 V

Voltage: 127 V or 220 V by state/municipality; confirm with the local distributor.

Notes

Voltage depends on state and even city: 127 V (with 220 V phase-to-phase) in much of the south-east and north, 220 V (with 380 V three-phase) in much of the north-east, centre-west and south. NBR 14136 type N is the national socket. Pass 3: Plug type N verified (ABNT standard reported by state engineering council); 127/220 V verified via distributor ANEEL bands; 60 Hz corroborated (VDE, ITA, WorldStandards).

Verified

Sources

  1. CREA-ES (state engineering council) - new socket standard mandatory (opens in a new tab)Brazilian ABNT plug/socket standard (NBR 14136, type N): 2- or 3-round-pin plugs, sockets always 3 holes; 4.0 mm pins up to 10 A and 4.8 mm pins 10-20 A; flat pins discontinued; overseen by Inmetro
  2. VDE (German electrical engineering association and standards publisher) - power supply when travelling (opens in a new tab)Independent listing: Brazil 127 V, 60 Hz, C/N
  3. Energisa - voltage level guide (ANEEL classification) (opens in a new tab)Both 127 V and 220 V are nominal supply voltages under ANEEL's adequacy bands (117-133 V and 202-231 V)
  4. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 60 Hz, many systems incl. 127/220 and 220/380 V
  5. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 127 V / 220 V, 60 Hz, C/N

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
110 V
Frequency
60 Hz
Three-phase
208 V

Notes

US-style supply. Frequency appears in only one secondary source. Check local rules.

Check local rules

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Notes

British-style BS 1363 sockets throughout.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older compilations give 220/380 V.

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type C, Type G
Most common
Type C
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older references list 220/380 V.

Notes

Many outlets are combination sockets accepting flat and round pins; earthing is often absent. Pass 3: Third independent listing (VDE) added.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Yes, earthed sockets are standard

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
347/600 V

Frequency: Frequency from secondary sources (not stated in the utility document opened).

Notes

120/240 V split-phase to homes; commercial three-phase is commonly 347/600 V, with 120/208 V in many buildings. Hydro-Quebec supply requirements confirm these levels.

Verified

Sources

  1. Hydro-Quebec Blue Book (electricity supply requirements) (opens in a new tab)Low-voltage supply is single-phase 120/240 V or three-phase 347/600 V; 120/208 V for existing installations
  2. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 60 Hz, 120/240 V, B
  3. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 120 V, 60 Hz, A/B

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Also quoted as 220 V.

Notes

Schuko (F). Pass 3: Upgraded: C/F agree across ANWB and WorldStandards.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)220 V; sockets type C (unearthed) or type F (earthed)
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type C, Type F
Most common
Type A
Earthed
Not recorded

Supply

Voltage
127 V / 110 V
Frequency
50 Hz / 60 Hz

Voltage: Bonaire 127 V (some 220 V); Saba/Sint Eustatius 110 V.

Frequency: Bonaire 50 Hz; Saba/Sint Eustatius 60 Hz.

Notes

Differs by island: Bonaire about 127 V 50 Hz (also 220 V outlets); Saba and Sint Eustatius about 110 V 60 Hz. Only one current secondary source available. Pass 3: Upgraded: voltages and plug types corroborated (ANWB + WorldStandards); per-island frequency single-source.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)Bonaire 127 V (220 V in newer buildings), Sint Eustatius and Saba 110 V; A/B sockets everywhere, C/F in some hotels on Bonaire and Sint Eustatius
  2. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: Netherlands Antilles: 50 Hz, 220 V, C/E (old, not island-specific)
  3. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: Bonaire 127/220 V 50 Hz; Saba & Sint Eustatius 110 V 60 Hz

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Yes, earthed sockets are standard

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
208 V

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E, Type F
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

E and F both reported. Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type L
Most common
Type L
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Italian-style type L and type C outlets.

Corroborated

Plugs and sockets

Types
Type A, Type C, Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Notes

Standard outlets are the GB 1002 angled three-pin (type I variant) plus a two-pin flat outlet. Older references list legacy types that are no longer standard. Pass 3: Voltage/frequency verified from national supply rules; plug forms (2-pin unearthed and 3-pin earthed) verified from GB 1002 notification. Type C acceptance on multi-standard outlets remains from secondary sources.

Verified

Sources

  1. Rules for Electricity Supply Business (供电营业规则, 2024), copy published by Shantou municipal government (opens in a new tab)Art. 6: rated supply frequency 50 Hz AC; Art. 7: low-voltage supply 220 V single-phase, 380 V three-phase (380/220 V four-wire); Art. 57: 220 V single-phase tolerance +7%/-10%
  2. WTO TBT notification G/TBT/N/CHN - draft GB 1002 household single-phase plugs and socket-outlets (types, parameters, dimensions) (opens in a new tab)National plug standard scope: single-phase, 50 Hz, rated 250 V, up to 32 A (10/16/32 A); two-pole unearthed and two-pole-plus-earth forms
  3. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 50 Hz, 220/380 V, C/D/G/H (outdated plug list)
  4. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, A/I

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Voltage: Often quoted as 110 V.

Notes

North American-style outlets.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Notes

Australian/NZ-style outlets.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
208 V

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type C, Type L
Most common
Type A
Earthed
Not recorded

Supply

Voltage
110 V
Frequency
60 Hz

Voltage: Some 220 V outlets also found.

Notes

Mostly 110-120 V US-style, but some 220 V outlets (often in hotels) with European plugs.

Corroborated

Plugs and sockets

Types
Type A, Type B, Type C, Type F
Most common
Type A
Earthed
Not recorded

Supply

Voltage
127 V
Frequency
50 Hz

Notes

US-style A/B outlets at 127 V are standard; some hotels and resorts also have European C/F outlets at 220 V. Frequency 50 Hz is reported by one compilation only - check before using clocks or motors. Pass 3: Upgraded: 127 V and A/B corroborated (ANWB + WorldStandards); 50 Hz still single-source.

Corroborated

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 240/415 V from before EU harmonisation.

Notes

British BS 1363 (G) sockets. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Pin-earth sockets (E); E/F hybrid plugs fit. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F, Type K
Most common
Type K
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Danish type K is the national socket; Schuko (F) sockets have also been allowed in new installations since 2011 (reported, not confirmed from the regulator text opened). Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Sikkerhedsstyrelsen notice Elmateriel 11/09 (opens in a new tab)Danish plug/socket parts to section 107-2-D1 (type K)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  5. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: corroborated, frequency: corroborated.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type D, Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

British-style supply.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
208 V

Notes

US-style supply; earthing often absent.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
208 V

Notes

North American-style outlets.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Often quoted as 220 V; nominal 220-230 V.

Notes

Sources disagree on the earthed type; many sockets are unearthed C. Pass 3: Upgraded from unverified: C/F and 50 Hz agree across WorldStandards, VDE and ANWB; voltage quoted as 220 V (ANWB) or 230 V (VDE).

Corroborated

Sources

  1. VDE (German electrical engineering association and standards publisher) - power supply when travelling (opens in a new tab)Independent listing: Egypt 230 V, 50 Hz, C/F
  2. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)220 V; two-round-hole sockets, unearthed (C) or earthed (F)
  3. ADAC (German automobile club) - destination facts (opens in a new tab)220 V, 50 Hz; no adapter needed for German plugs
  4. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  5. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  6. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220 V.

Notes

Sources disagree on plug types. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E, Type L
Most common
Type C
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Mixed C/E/L; sources disagree. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type M, Type N
Most common
Type M
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

South African M (and newer N) reported; older US list shows D. Pass 3: Upgraded: M/N (and C plugs) corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; type M sockets, type N in many newer buildings; C plugs fit N
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F, Type G
Most common
Type F
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: The national utility describes its LV network as 380/220 V; some references give 230/400 V.

Notes

Mixed C/F/G; sources disagree. Pass 3: Correction: voltage 220/380 V per the utility (was 230/400 V). Plug types C/F/G remain unverified (sources disagree). Check local rules.

Check local rules

Sources

  1. Ethiopian Electric Utility - EEU's Facts in 2021/22 (opens in a new tab)Low-voltage distribution lines at 380/220 V
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Notes

British-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type E, Type F, Type K
Most common
Type K
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Danish practice (type K) generally followed; only one source found. Pass 3: Upgraded; type E added.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; Danish type K plus C, E and F sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Notes

Australian/NZ-style outlets.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Pin-earth sockets (E) to NF C 61-314; E/F hybrid plugs fit. Field confidence - plugs: verified, voltage: verified, frequency: verified.

Verified

Sources

  1. CRE (French energy regulator): Qualité de l'onde de tension (opens in a new tab)50 Hz; 230 V single-phase / 400 V three-phase at low voltage
  2. VDE: Power supply and safety when travelling (opens in a new tab)Plug types, voltage and 50 Hz for listed European countries (German standards body)
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

French-style supply (French overseas department). Pass 3: 230/400 V and 50 Hz verified from EDF's overseas terms of sale; plug types corroborated only.

Corroborated

Sources

  1. EDF SEI - general terms of sale for residential customers in Corsica and the French overseas territories (2023) (opens in a new tab)Sec. 5-1: nominal 230 V single-phase / 400 V three-phase (207-253 V / 360-440 V, per NF EN 50160); nominal frequency 50 Hz, 60 Hz for Saint-Martin and Saint-Barthélemy; covers Réunion, Guadeloupe, Martinique, French Guiana, Saint-Pierre-et-Miquelon
  2. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 50 Hz, 220 V, C/E
  3. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, C/E

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type E
Most common
Type E
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
60 Hz
Three-phase
380 V

Voltage: Older data gives 127/220 V systems.

Notes

Unusual 220 V at 60 Hz; French-style and US-style outlets both found. Sources disagree on plug types.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

BS 1363 (G). Pass 3: Upgraded: type G and 230 V agree across ANWB and WorldStandards.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; earthed sockets with three rectangular holes (type G)
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Schuko-type outlets common; legacy unearthed sockets in older housing.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard; Europlug (C) widely used for small appliances. Field confidence - plugs: verified, voltage: verified, frequency: verified.

Verified

Sources

  1. VDE: Power supply and safety when travelling (opens in a new tab)Plug types, voltage and 50 Hz for listed European countries (German standards body)
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type D, Type G
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Sources disagree (230 V vs 240/415 V).

Notes

Type G (BS 1363) is the official outlet; three-round-pin type D also found, and universal outlets accepting C/F plugs are common. Pass 3: Voltage 230 V corroborated (ANWB + WorldStandards); type D added.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; type G and type D sockets; universal sockets common
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 240/415 V; current nominal not confirmed from a local source.

Notes

British BS 1363 (G) sockets. Pass 3: Upgraded: G and 230 V corroborated (ANWB + WorldStandards); type C occasionally seen.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; earthed type G sockets, occasionally type C
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F, Type K
Most common
Type K
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Nominal 230/400 V per Nukissiorfiit.

Notes

Danish type K used. Pass 3: Upgraded: 230/400 V verified from the national utility; plug types (K with C/F) corroborated by two compilations.

Corroborated

Sources

  1. Nukissiorfiit (Greenland national utility) - general terms for public electricity supply no. 4 (2026) (opens in a new tab)Sec. 2.4: nominal supply voltage 3 x 230/400 V
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

British-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type D, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

French-style supply (French overseas department). Pass 3: 230/400 V and 50 Hz verified from EDF's overseas terms of sale; plug types corroborated only.

Corroborated

Sources

  1. EDF SEI - general terms of sale for residential customers in Corsica and the French overseas territories (2023) (opens in a new tab)Sec. 5-1: nominal 230 V single-phase / 400 V three-phase (207-253 V / 360-440 V, per NF EN 50160); nominal frequency 50 Hz, 60 Hz for Saint-Martin and Saint-Barthélemy; covers Réunion, Guadeloupe, Martinique, French Guiana, Saint-Pierre-et-Miquelon
  2. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 50 Hz, 220 V, C/E
  3. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, C/E

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Voltage: Also quoted as 110 V.

Notes

US-style supply and outlets.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

UK-style BS 1363 (G). Only one source found; not CENELEC/UK-law covered. Pass 3: Upgraded: G and 230 V corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; type G sockets, type C may also occur
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Sources disagree on plug types. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Sources disagree on plug types. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type D, Type G
Most common
Type B
Earthed
Not recorded

Supply

Voltage
120 V / 240 V
Frequency
60 Hz

Voltage: Both 110-120 V and 220-240 V outlets found.

Frequency: One source mentions 50 Hz in places.

Notes

Both 120 V and 240 V outlets exist; check each outlet. One source suggests some 50 Hz areas.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
110 V
Frequency
60 Hz

Notes

US-style supply; supply is unreliable.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Voltage: Also quoted as 110 V.

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Notes

BS 1363 13 A sockets are standard; older round-pin 5 A/15 A sockets (types D/M) still found. EMSD confirms 220 V household supply.

Verified

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type M
Most common
Type D
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Round-pin 6 A (type D) and 16 A (type M) outlets; two-pin type C plugs fit most sockets. Pass 3: Older IS 12360:1988 used 240/415 V; current supply codes and the BIS revision use 230/400 V.

Verified

Sources

  1. Delhi Electricity Regulatory Commission - Draft Supply Code (regulation 3) (opens in a new tab)Declared frequency 50 Hz; low-tension supply 230 V single-phase (phase-neutral), 400 V three-phase
  2. Bureau of Indian Standards - draft revision of IS 12360 (voltage bands, preferred voltage and frequency), 2024 (opens in a new tab)Standard frequency 50 Hz; preferred LV 230/400 V aligned to IEC 60038, replacing the older 240/415 V values
  3. IS 1293:2005 plugs and socket-outlets up to 250 V and 16 A (public copy, law.resource.org) (opens in a new tab)National plug standard: 2-pole (class II only) and 2-pole+earth types at 6 A, 10 A and 16 A, 230-250 V (corresponding to types D and M); 2-pin plugs for class II appliances only
  4. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 50 Hz, 230/400 V, C/D/G
  5. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, D/M

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older references list 220/380 V.

Notes

Schuko-type outlets standard. Pass 3: Third independent listing (VDE) added. A PLN Institute of Technology thesis gives the secondary distribution nominal as 231/400 V, supporting 230 V (official PLN/ESDM text not opened).

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

Sources disagree on the earthed type (F vs E). Pass 3: Iran's National Building Regulations (Mabhas 13) require single-phase sockets of at least 16 A with a protective-earth contact, consistent with Schuko-type outlets; E vs F still unresolved. Check local rules.

Check local rules

Sources

  1. Iran National Building Regulations, Topic 13 - design and installation of electrical installations (Ministry of Housing, hosted by Univ. of Hormozgan) (opens in a new tab)Sec. 13-7-2: single-phase sockets must have an earth contact and be rated at least 16 A
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type G
Most common
Type G
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Iraqi sources give 220 V / 380 V; some compilations list 230 V.

Notes

Universal multi-type sockets very common; G and C both used. Pass 3: Voltage corrected to 220/380 V: an Iraqi university lecture (Ministry of Electricity supply) and the US ITA list both give 220/380 V, 50 Hz. Plug types still unverified. Check local rules.

Check local rules

Sources

  1. Mustansiriyah University (Baghdad) lecture notes - sources of electricity (opens in a new tab)Iraq supply via Ministry of Electricity companies: single-phase 220 V, three-phase 380 V, 50 Hz
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: ESB Networks supplies 207-253 V (230 V ±10%, EN 50160).

Notes

BS 1363-type (G) sockets; VDE notes the Europlug does not fit in Ireland. Field confidence - plugs: corroborated, voltage: verified, frequency: corroborated.

Corroborated

Sources

  1. ESB Networks: What is the standard voltage in Ireland (opens in a new tab)Supply delivered at 207-253 V per EN 50160 (i.e. 230 V ±10%)
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  5. VDE: Power supply and safety when travelling (opens in a new tab)Plug types, voltage and 50 Hz for listed European countries (German standards body)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

UK-style BS 1363 (G). Only one source found. Field confidence - plugs: unverified, voltage: unverified, frequency: unverified. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type H
Most common
Type H
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Some sources still give 220 V.

Notes

Israeli SI 32 (type H); Europlug (C) fits. Pass 3: Third independent listing (VDE) added. VDE additionally lists M.

Corroborated

Sources

  1. VDE (German electrical engineering association and standards publisher) - power supply when travelling (opens in a new tab)Independent listing: Israel 230 V, 50 Hz, C/H/M
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Interpower: Israel national power mains (opens in a new tab)SI 32 (type H) plug, 50 Hz (lists 220 V)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F, Type L
Most common
Type L
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Italian type L and Schuko (F) both common; many sockets are bipasso/universal L+F. Field confidence - plugs: verified, voltage: verified, frequency: verified.

Verified

Sources

  1. VDE: Power supply and safety when travelling (opens in a new tab)Plug types, voltage and 50 Hz for listed European countries (German standards body)
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
110 V
Frequency
50 Hz

Notes

Unusual 110 V at 50 Hz: US 60 Hz appliances with motors or clocks may misbehave.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
100 V
Frequency
50 Hz / 60 Hz
Three-phase
200 V

Frequency: 50 Hz in the east (Tokyo, Tohoku, Hokkaido); 60 Hz in the west (Nagoya, Osaka, Kyushu).

Notes

Lowest mains voltage in the world. Two grids at different frequencies meet along the Fuji River-Itoigawa line; frequency converters link them. Two-pin type A outlets dominate; earthed type B in kitchens/laundries.

Verified

Sources

  1. METI energy education material (energy-kyoiku.meti.go.jp) (opens in a new tab)50 Hz east / 60 Hz west split at the Fuji River (Shizuoka) and Itoigawa (Niigata); 100 V/200 V distribution transformers to homes
  2. TEPCO - Transformation (substations) (opens in a new tab)Supply is 50 Hz in eastern Japan and 60 Hz in the west
  3. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 50/60 Hz by region, 100/200 V, A/B
  4. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 100 V, 50/60 Hz, A/B

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

UK-style BS 1363 (G). Only one source found. Pass 3: Upgraded: G, 230 V and 50 Hz corroborated (ANWB, Ports of Jersey, WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; type G sockets, type C may also occur
  2. Ports of Jersey - Port notice: electricity cables and supply (opens in a new tab)Supply 220-250 V, 50 Hz (marina shore supply)
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F, Type G
Most common
Type F
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Mixed C/F/G (and some D, L). Field confidence - plugs: corroborated, voltage: corroborated, frequency: corroborated.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Former Soviet standard; Schuko-type outlets common. Pass 3: Third independent listing (VDE) added.

Corroborated

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Notes

BS 1363 (G). Pass 3: Third independent source agrees: type G, 240 V.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)240 V; earthed type G sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Voltage: Older data gives 220 V.

Notes

Australian/NZ-style outlets.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Only one source found. Pass 3: Upgraded: C/F corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)No adapter needed: Dutch (type C/F) plugs fit almost all sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Voltage: WorldStandards gives 230 V; US government and Schneider sources give 240/415 V. Not confirmed from MEW text.

Notes

BS 1363 (G); some C seen. Field confidence - plugs: corroborated, voltage: corroborated, frequency: corroborated.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Former Soviet standard; Schuko-type outlets common. Pass 3: Third independent listing (VDE) added.

Corroborated

Plugs and sockets

Types
Type A, Type B, Type C, Type E, Type F
Most common
Type C
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older references list 220/380 V.

Notes

Mixed outlet types; universal sockets common.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Some sources still give 220 V.

Notes

Sources disagree on the earthed type (F vs E); F is generally reported. Pass 3: Upgraded: C/F corroborated (ANWB + WorldStandards); 230 V 50 Hz per EU harmonisation (HD 472).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)No adapter needed: Dutch (type C/F) plugs fit almost all sockets
  2. ADAC (German automobile club) - destination facts (opens in a new tab)220 V (older figure), 50 Hz; no adapter needed
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  6. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V (some 110/190 V historically).

Notes

Mixed sockets; sources disagree. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type M
Most common
Type M
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

South African M reported; US list shows D. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type F, Type G
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: US government list gives 120/240 V.

Frequency: US government list gives 60 Hz; WorldStandards gives 50 Hz.

Notes

Very mixed: legacy US-style 120 V/60 Hz installations and newer 230 V/50 Hz supply; universal sockets common. Field confidence - plugs: unverified, voltage: unverified, frequency: unverified. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F, Type L
Most common
Type F
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Some 127/220 V reported historically.

Notes

Mixed C/F/L; US list shows L only. Field confidence - plugs: unverified, voltage: corroborated, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type J
Most common
Type J
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220 V.

Notes

Swiss type J system used. Pass 3: Upgraded: C/J and 230 V corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; unearthed type C or earthed three-round-hole type J sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Some sources still give 220 V.

Notes

Sources disagree on the earthed type (F vs E); F is generally reported. Pass 3: Upgraded: C/F corroborated (ANWB + WorldStandards); 230 V 50 Hz per EU harmonisation (HD 472).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)No adapter needed: Dutch (type C/F) plugs fit almost all sockets
  2. ADAC (German automobile club) - destination facts (opens in a new tab)230 V, 50 Hz; no adapter needed
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  6. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

BS 1363 type G is now normal; older round-pin types D/M remain in some buildings.

Corroborated

Plugs and sockets

Types
Type C, Type D, Type E, Type J, Type K
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: ANWB reports 127 V or 220 V depending on location; nominal 220-230 V in most areas. Check appliance ratings.

Notes

Pin-earth (E) with mixed older types. Pass 3: Correction: plug list widened (C/E plus J, K and D); 127 V supply in some places noted.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)127 V or 220 V; type E and C common; types J and K also found; type D rare in older buildings
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

BS 1363 (G). Pass 3: Third independent source agrees.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; earthed type G sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Voltage: Harmonised nominal 230 V; often measured nearer 240 V.

Notes

BS 1363 sockets throughout. Nominal is being harmonised to 230/400 V; 240 V is still commonly quoted. Pass 3: Third independent listing (VDE) added. VDE also lists A/C/M; BS 1363 type G remains the installed standard - other types are likely adapter/legacy listings.

Corroborated

Plugs and sockets

Types
Type C, Type D, Type G, Type J, Type K, Type L
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Resorts often have British-style or universal sockets; local outlets vary.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V with some 127 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 240/415 V.

Notes

British BS 1363 (G) sockets. Field confidence - plugs: corroborated, voltage: verified, frequency: verified.

Corroborated

Sources

  1. Enemalta: Technical service specifications (opens in a new tab)230 V phase-neutral, 400 V phase-phase, 50 Hz
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Notes

US-style supply. Only one secondary source could be checked. Check local rules.

Check local rules

Sources

  1. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 120 V, 60 Hz, A/B

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

French-style supply (French overseas department). Pass 3: 230/400 V and 50 Hz verified from EDF's overseas terms of sale; plug types corroborated only.

Corroborated

Sources

  1. EDF SEI - general terms of sale for residential customers in Corsica and the French overseas territories (2023) (opens in a new tab)Sec. 5-1: nominal 230 V single-phase / 400 V three-phase (207-253 V / 360-440 V, per NF EN 50160); nominal frequency 50 Hz, 60 Hz for Saint-Martin and Saint-Barthélemy; covers Réunion, Guadeloupe, Martinique, French Guiana, Saint-Pierre-et-Miquelon
  2. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 50 Hz, 220 V, C/E
  3. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, C/E

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Sources disagree on plug types. Field confidence - plugs: unverified, voltage: corroborated, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E, Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Type G (BS 1363) earthed outlets and unearthed two-pin type C outlets, often side by side; French-style type E is listed by some compilations but not by ANWB. Pass 3: C and G confirmed by ANWB; type E kept but less certain.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; unearthed type C and earthed type G sockets, often side by side
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

French practice; only one source found. Pass 3: 230/400 V and 50 Hz (47-52 Hz band) verified from the Mayotte utility; plug types single-source. Check local rules.

Check local rules

Sources

  1. Électricité de Mayotte - general terms of sale, residential customers up to 36 kVA (2023) (opens in a new tab)Sec. 5-1: nominal 230 V single-phase / 400 V three-phase (207-244 V / 360-424 V); frequency between 47 and 52 Hz
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
127 V
Frequency
60 Hz
Three-phase
220 V

Notes

Nominal 127 V (often called 110/120 V); three-phase 220/127 V in many buildings. Pass 3: Voltage/frequency verified (federal technical norm: 220/127 V, 60 Hz); plug types A/B corroborated by three independent compilations.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Notes

US-style supply is generally reported, but no source checked in this pass lists Micronesia. Check local rules.

Check local rules

Sources

No published source has been recorded for this entry. Check local rules with the national regulator or supply company.

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

Sources disagree on the earthed type. Pass 3: Upgraded: C/F corroborated (ANWB + WorldStandards). ADAC confirms 230 V 50 Hz.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)No adapter needed: Dutch (type C/F) plugs fit almost all sockets
  2. ADAC (German automobile club) - destination facts (opens in a new tab)230 V, 50 Hz; no adapter needed
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type E, Type F
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source lists mixed 127/220 and 220/380 V.

Notes

French-style outlets: type E (earth pin) and unearthed type C; type F also reported, and some old type D three-round-hole outlets remain. Pass 3: Upgraded; F and legacy D added to plug list.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; types C, E and F; old type D sockets still found in places
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type C
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older references list 220 V.

Notes

European round-pin outlets; type E/F earthed outlets in newer buildings.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220 V.

Notes

Sources disagree on the earthed type (F vs E). Pass 3: Upgraded: 50 Hz and C/F compatibility corroborated by ADAC; voltage quoted 220 V (nominal 230 V).

Corroborated

Sources

  1. ADAC (German automobile club) - Montenegro: good to know (opens in a new tab)Mains 220 V at 50 Hz; no adapter needed for German (C/F) plugs
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type G
Most common
Type A
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
60 Hz

Notes

230 V at 60 Hz; sources disagree on outlet types.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V with some 127/220 V.

Notes

Pin-earth (E). Pass 3: Upgraded: C/E agree across ANWB and WorldStandards; voltage 220-230 V. ADAC also states C/E.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)220 V; sockets type E (earth pin) and unearthed type C
  2. ADAC (German automobile club) - destination facts (opens in a new tab)220 V, 50 Hz; type C and type E plugs/sockets
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F, Type M, Type N
Most common
Type C
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Quoted as 220 V by ANWB and older sources; nominal 220-230 V.

Notes

Most outlets are two-round-hole type C or type F; South African type M appears in newer hotels and coastal resorts and type N in new or renovated buildings. Pass 3: Upgraded: C/F/M/N corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)220 V; mostly type C/F; type M in newer hotels/coastal resorts; type N in new/renovated buildings
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type F, Type G
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Wide mix of outlet types; universal sockets common. Supply reliability is variable.

Corroborated

Plugs and sockets

Types
Type C, Type D, Type M, Type N
Most common
Type M
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220/380 V.

Notes

Type M (large three round pins) is the standard outlet; type D appears in older buildings and type N in newer or renovated ones. Two-pin C plugs fit N outlets. Pass 3: Upgraded; correction: type D added (older buildings). Voltage 220-230 V.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)220 V; standard earthed type M sockets, type D in older buildings, type N in many newer buildings
  2. ADAC (German automobile club) - destination facts (opens in a new tab)220 V, 50 Hz; some sockets not compatible with German plugs
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Notes

Australian-style outlets. Only one secondary source could be checked. Check local rules.

Check local rules

Plugs and sockets

Types
Type C, Type D, Type M
Most common
Type D
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older references list 220/380 V.

Notes

Indian-style round-pin outlets dominate.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

French-style supply.

Corroborated

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Frequency: Must be held within 1.5% of 50 Hz.

Notes

AS/NZS 3112 type I outlets. Standard low voltage and frequency are set in law (Electricity (Safety) Regulations 2010).

Verified

Sources

  1. Electricity (Safety) Regulations 2010 (legislation.govt.nz) (opens in a new tab)Reg 4: standard low voltage 230 V AC phase-neutral; reg 29: frequency 50 Hz within 1.5%
  2. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 50 Hz, 230/400 V, 'H' (older letter for type I)
  3. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, I

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: corroborated, frequency: corroborated.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

BS 1363 (G) generally reported; universal multi-type sockets common. US list shows C/D/H. Pass 3: Upgraded: voltage and frequency verified from a federal agency standard; type G (British-standard sockets) corroborated by REA + WorldStandards; multi-type 'universal' sockets common.

Corroborated

Sources

  1. Rural Electrification Agency of Nigeria - Harmonised Technical Standards (designs and specifications), 2021 (opens in a new tab)LV supply 230 V ±6% phase-neutral and 400 V ±6% phase-phase per the Nigerian distribution code; 50 Hz; protective conductor required for all British-standard sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

NZ-style supply. Only one secondary source could be checked. Check local rules.

Check local rules

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older data gives 240 V.

Notes

Australian-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type C
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Frequency: One older source lists 60 Hz; 50 Hz is the more widely reported value.

Notes

Sources disagree on frequency (one older government list gives 60 Hz). Little reliable public information. Check local rules.

Check local rules

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Voltage: Older data gives 115 V.

Notes

US-style supply. Only an old government list (115 V, 60 Hz) was available. Check local rules.

Check local rules

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Many older Norwegian networks are 230 V IT (three-phase 230 V line-to-line, no neutral). Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Voltage: WorldStandards gives 230 V; two older sources give 240/415 V.

Notes

BS 1363 (G) generally reported; US list shows H (likely error). Pass 3: Upgraded: G and 240 V corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)240 V; earthed type G sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D
Most common
Type D
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Round-pin type D outlets common; British type G also found. Pass 3: Voltage/frequency verified from the regulator; plug types (C/D, with G also seen) corroborated only.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type H
Most common
Type H
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Israeli-type H and Europlug C; only one source found. Field confidence - plugs: unverified, voltage: unverified, frequency: unverified. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Notes

Australian-style outlets.

Corroborated

Plugs and sockets

Types
Type C
Most common
Type C
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Europlug-style outlets; Brazilian type N also seen.

Corroborated

Plugs and sockets

Types
Type A, Type C
Most common
Type C
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
60 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

220 V at 60 Hz; combination outlets accept flat and round pins.

Corroborated

Plugs and sockets

Types
Type A, Type B, Type C
Most common
Type A
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
60 Hz

Voltage: Quoted as 220-240 V depending on source.

Notes

60 Hz like the USA but at 220-230 V, so US 120 V-only appliances need a transformer. Outlets usually accept flat-pin plugs; earthing often absent. Pass 3: 60 Hz verified from regulator rules; 220-230 V and plug types A/B/C corroborated only.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Pin-earth sockets (E). Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Yes, earthed sockets are standard

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
208 V

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Voltage: 240/415 V ±6% (Kahramaa Wiring Code 2018).

Notes

BS 1363 (G) 13 A sockets; BS 546 (D/M) also seen. Field confidence - plugs: corroborated, voltage: verified, frequency: verified.

Corroborated

Sources

  1. Kahramaa Electricity Wiring Code 2018 (opens in a new tab)240/415 V ±6%, 3-phase 4-wire, 50 Hz; 13 A switched socket outlets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: GOST 29322-2014 (IEC 60038) sets 230/400 V, but the power-quality standard GOST 32144-2013 still states 220 V phase-neutral / 380 V phase-phase; treat as 220-230 V.

Notes

Schuko-type (F) sockets; older Soviet sockets accept only thin-pin plugs. Pass 3: Frequency verified; nominal voltage verified as 220/380 V in GOST 32144 alongside 230/400 V in GOST 29322 (both in force); plug types C/F corroborated (VDE lists C/F).

Corroborated

Sources

  1. GOST 32144-2013 Electric energy - power quality limits (text copy) (opens in a new tab)Cl. 4.2.1: nominal frequency 50 Hz (±0.2 Hz 95% of week); cl. 4.2.2: nominal LV supply 220 V phase-neutral, 380 V phase-phase; voltage deviation within ±10%
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. VDE: Power supply and safety when travelling (opens in a new tab)Plug types, voltage and 50 Hz for listed European countries (German standards body)
  4. NormaCS expert answer on GOST 29322-2014 (opens in a new tab)GOST 29322-2014 (IEC 60038) 230/400 V mandatory in Customs Union states, though older documents still cite 220/380 V
  5. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  6. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E, Type F, Type G
Most common
Type F
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

Mixed; sources disagree. Pass 3: 230/400 V verified from the regulator; plug list still disputed. Check local rules.

Check local rules

Sources

  1. RURA - Draft Regulation Governing Electrical Installation Services 2023 (opens in a new tab)Single-phase installations 230 V, three-phase LV 400 V; plugs/sockets to RS IEC 60884-1
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

French practice (overseas department); only one source found. Pass 3: 230/400 V and 50 Hz verified from EDF's overseas terms of sale; plug types C/E from one compilation only (French installation practice). Check local rules.

Check local rules

Sources

  1. EDF SEI - general terms of sale for residential customers in Corsica and the French overseas territories (2023) (opens in a new tab)Sec. 5-1: nominal 230 V single-phase / 400 V three-phase (207-253 V / 360-440 V, per NF EN 50160); nominal frequency 50 Hz, 60 Hz for Saint-Martin and Saint-Barthélemy; covers Réunion, Guadeloupe, Martinique, French Guiana, Saint-Pierre-et-Miquelon
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
60 Hz

Notes

French-style outlets at 60 Hz. Only one secondary source available. Pass 3: 230 V and 60 Hz verified from EDF's terms of sale; plug types single-source. Check local rules.

Check local rules

Sources

  1. EDF SEI - general terms of sale for residential customers in Corsica and the French overseas territories (2023) (opens in a new tab)Sec. 5-1: nominal 230 V single-phase / 400 V three-phase (207-253 V / 360-440 V, per NF EN 50160); nominal frequency 50 Hz, 60 Hz for Saint-Martin and Saint-Barthélemy; covers Réunion, Guadeloupe, Martinique, French Guiana, Saint-Pierre-et-Miquelon
  2. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 60 Hz, C/E

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

UK-style (G); only one source found. Field confidence - plugs: unverified, voltage: unverified, frequency: unverified. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type D, Type G
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
60 Hz

Notes

230 V at 60 Hz; some US-style outlets in hotels.

Corroborated

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Voltage: Also quoted as 230 V.

Notes

British-style supply.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
60 Hz

Voltage: Also quoted as 220 V.

Notes

French-style outlets at 60 Hz. Only one secondary source available. Pass 3: Upgraded: C/E and 220-230 V corroborated (ANWB + WorldStandards); 60 Hz single-source. 230 V and 60 Hz verified from EDF's terms of sale.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)French side (Saint-Martin) 220 V with type C/E sockets
  2. EDF SEI - general terms of sale for residential customers in Corsica and the French overseas territories (2023) (opens in a new tab)Sec. 5-1: nominal 230 V single-phase / 400 V three-phase (207-253 V / 360-440 V, per NF EN 50160); nominal frequency 50 Hz, 60 Hz for Saint-Martin and Saint-Barthélemy; covers Réunion, Guadeloupe, Martinique, French Guiana, Saint-Pierre-et-Miquelon
  3. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 60 Hz, C/E

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Frequency: One older source lists 60 Hz.

Notes

French-style supply: EDF supplies 230 V / 400 V at 50 Hz. An older US list giving 115 V 60 Hz with US plugs is out of date. Pass 3: 230/400 V and 50 Hz verified from EDF's overseas terms of sale; plug types C/E from one compilation only (French installation practice). This resolves the old 115 V / 60 Hz conflict in favour of 230 V / 50 Hz. Check local rules.

Check local rules

Sources

  1. EDF SEI - general terms of sale for residential customers in Corsica and the French overseas territories (2023) (opens in a new tab)Sec. 5-1: nominal 230 V single-phase / 400 V three-phase (207-253 V / 360-440 V, per NF EN 50160); nominal frequency 50 Hz, 60 Hz for Saint-Martin and Saint-Barthélemy; covers Réunion, Guadeloupe, Martinique, French Guiana, Saint-Pierre-et-Miquelon
  2. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 60 Hz, 115 V, A/B (older data)
  3. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, C/E

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type C, Type E, Type G, Type I, Type K
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Some small islands (e.g. Petit Saint Vincent) 110 V.

Frequency: Some small islands 60 Hz.

Notes

Mainly British-style on Saint Vincent; mixed types on the Grenadines; a few small islands run at 110 V 60 Hz.

Corroborated

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Australian/NZ-style outlets.

Corroborated

Plugs and sockets

Types
Type C, Type F, Type L
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220 V.

Notes

Italian practice (L and F); sources disagree. Pass 3: Upgraded: C/F/L and 230 V corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; Italian type L most common, also F and C; combination and 16 A type L sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
60 Hz
Three-phase
400 V

Voltage: National system moved from 127/220 V to 230/400 V; 127 V being phased out.

Frequency: 60 Hz (unlike most of the region).

Notes

SASO 2203 (BS 1363-based, G) for 230 V; older 127 V US-style (A/B) sockets remain in some buildings. Field confidence - plugs: verified, voltage: verified, frequency: corroborated.

Corroborated

Sources

  1. SASO: Plugs and sockets campaign (opens in a new tab)SASO 2203 (BS 1363-based, 13 A) for 220/230 V; move from 127/220 V to 230/400 V with 127 V being phased out
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 127/220 V.

Notes

Pin-earth (E). Field confidence - plugs: corroborated, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Sources disagree on the earthed type (F vs E); F is generally reported. Pass 3: Upgraded: C/F corroborated (ANWB + WorldStandards). ADAC confirms 230 V 50 Hz.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)No adapter needed: Dutch (type C/F) plugs fit almost all sockets
  2. ADAC (German automobile club) - destination facts (opens in a new tab)230 V, 50 Hz; no adapter needed
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  6. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Sources disagree (240 V vs 230/400 V).

Notes

BS 1363 (G) generally reported; US list shows D. Pass 3: Upgraded: 240 V 50 Hz corroborated (ADAC + WorldStandards); type G consistent with adapter requirement.

Corroborated

Sources

  1. ADAC (German automobile club) - destination facts (opens in a new tab)240 V, 50 Hz; travel adapter needed for German plugs
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

BS 1363 (G). Field confidence - plugs: corroborated, voltage: corroborated, frequency: corroborated.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

BS 1363 13 A sockets standard. Pass 3: Third independent listing (VDE) added. VDE also lists C/M; type G is the installed standard.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
110 V
Frequency
60 Hz

Notes

US-style supply. Only one current secondary source; older data for the former Netherlands Antilles differs. Pass 3: Upgraded: 110 V and A/B corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)Dutch side 110 V with type A/B sockets; French side 220 V with type C/E
  2. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 110 V, 60 Hz, A/B

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Pin-earth sockets (E). Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Sources disagree on the earthed type (F vs E); F is generally reported. Pass 3: Upgraded: 230 V 50 Hz verified by national tourist board; type C verified, type F corroborated (WorldStandards).

Corroborated

Sources

  1. Slovenian Tourist Board (slovenia.info) - mobile phones, mains voltage, radio (opens in a new tab)Mains 230 V, 50 Hz; European plug CEE 7/16 (type C) as in most of Europe
  2. ADAC (German automobile club) - destination facts (opens in a new tab)230 V, 50 Hz; no adapter needed
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  6. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G, Type I
Most common
Type I
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Quoted as 220-240 V.

Notes

Australian-style outlets; some British-style.

Corroborated

Plugs and sockets

Types
Type C, Type G
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Voltage varies by area in older sources (110-230 V).

Notes

Universal sockets very common. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type M, Type N
Most common
Type M
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Nominal 230 V single-phase / 400 V three-phase with ±10% at the customer point under NRS 048-2; older installations quoted 220-250 V.

Notes

Large 3-pin M (SANS 164-1) dominant; N (SANS 164-2) preferred for new installations; Europlug C fits N sockets. Pass 3: Now verified: plug system (SANS 164), 230/400 V (municipal distributor citing NRS 048-2) and 50 Hz (Eskom).

Verified

Sources

  1. City of Cape Town (municipal distributor) - Grid interconnection of embedded generation, Part 2 sec. 3 (opens in a new tab)Shared LV feeders at 400 V/230 V; customer LV voltage within ±10% per NRS 048-2
  2. Government Gazette 35552 (DTI, Standards Act) 3 Aug 2012 (opens in a new tab)SANS 164-0 plug and socket-outlet systems for use in South Africa; SANS 164-2 16 A 250 V system aligned with IEC 60906-1 (type N)
  3. SouthAfrica.info: ZA plug conversion explained (opens in a new tab)SANS 164-2 (type N) preferred for new installations; triangular 3-pin (type M) still in use during transition
  4. Eskom: Quality of supply brochure (opens in a new tab)50 Hz utility frequency in South Africa
  5. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  6. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  7. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
60 Hz
Three-phase
380 V

Notes

Converted from 110 V to 220 V over several decades; Schuko-type (KS C 8305) outlets now standard. Pass 3: Third independent listing (VDE) added. VDE still lists legacy 110 V; 220 V is standard. Frequency 60 Hz (±0.2 Hz) verified from the government notice; 220 V ±13 V / 380 V ±38 V reported from KEPCO's supply terms via a secondary summary.

Corroborated

Plugs and sockets

Types
Type C, Type D, Type G
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Mixed/universal sockets; only one source found. Field confidence - plugs: unverified, voltage: unverified, frequency: unverified. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Fixed household outlets are 16 A 2P+earth Schuko-type (UNE 20315 figure C2a, type F); French pin-earth type E (C3a) is reserved for installations needing phase/neutral distinction; 25 A cooker outlets use ESB 25-5a. Pass 3: Now verified from national regulation: 230/400 V, 50 Hz, type F (C2a) outlets; type C plugs fit.

Verified

Sources

  1. BOE - Real Decreto 842/2002, Reglamento electrotécnico para baja tensión (REBT), consolidated text (opens in a new tab)Art. 4: 230 V phase-neutral / 400 V between phases, network frequency 50 Hz; ITC-BT-19/25: fixed outlets UNE 20315 figure C2a (16 A 2p+T, Schuko) with C3a reserved, 25 A ESB 25-5a
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  5. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type D, Type G, Type M
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

British type G and round-pin D/M sockets both widespread.

Corroborated

Plugs and sockets

Types
Type C, Type D, Type G
Most common
Type D
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 240/415 V.

Notes

Mixed C/D/G; universal sockets common. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type C, Type F
Most common
Type F
Earthed
Not recorded

Supply

Voltage
127 V
Frequency
60 Hz
Three-phase
220 V

Voltage: Also quoted as 110 V.

Notes

Sources disagree on outlet types (US-style vs European). Low voltage with 60 Hz.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Schuko (F) standard. Field confidence - plugs: corroborated, voltage: corroborated, frequency: verified.

Corroborated

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type J
Most common
Type J
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Swiss SN 441011 system (type J); Europlug (C) fits. Field confidence - plugs: verified, voltage: verified, frequency: verified.

Verified

Sources

  1. VDE: Power supply and safety when travelling (opens in a new tab)Plug types, voltage and 50 Hz for listed European countries (German standards body)
  2. ESTI: Swiss household plug and socket system (SN 441011) (opens in a new tab)Swiss national plug/socket system is SN 441011 (type J family)
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E, Type F, Type L
Most common
Type F
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

Mixed; sources disagree. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older source gives 220 V.

Notes

Sources disagree on plug types. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
110 V
Frequency
60 Hz
Three-phase
380 V

Notes

North American-style outlets; 220 V circuits used for large appliances and air conditioning. Pass 3: Third independent listing (VDE) added.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Former Soviet standard.

Corroborated

Plugs and sockets

Types
Type D, Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Type G (BS 1363) is the norm; three-round-pin type D outlets remain in older buildings; some hotels have universal outlets taking C/F plugs. Pass 3: Type D added to plug list (older buildings) per ANWB and the existing note.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; most sockets type G, type D in older buildings, universal sockets in some hotels
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B, Type C, Type F, Type O
Most common
Type O
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older references list 220/380 V.

Notes

Thailand's own earthed type O (TIS 166-2549) is the national standard; many existing combination sockets accept flat and round pins. Pass 3: Third independent listing (VDE) added. VDE quotes 220 V and does not list type O.

Corroborated

Plugs and sockets

Types
Type C, Type E, Type F, Type I
Most common
Type I
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Australian-style type I and European types both found. Only one secondary source could be checked. Check local rules.

Check local rules

Sources

  1. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, C/E/F/I

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V with some 127/220 V.

Notes

Sources disagree on plug types. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Notes

Australian/NZ-style outlets.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
115 V
Frequency
60 Hz
Three-phase
230 V

Notes

US-style outlets at 115 V; 230 V circuits for larger loads.

Corroborated

Plugs and sockets

Types
Type C, Type E
Most common
Type E
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

Pin-earth (E). Pass 3: Upgraded: C/E and 230 V agree across ANWB and WorldStandards.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; sockets type C (unearthed) and type E (earth pin)
  2. ADAC (German automobile club) - destination facts (opens in a new tab)230 V, 50 Hz; Schuko plugs fit only where the socket has a hole for the earth pin (type E)
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Frequently quoted as 220 V; nominal 230 V under harmonised standards.

Notes

Schuko (F) standard. Pass 3: Upgraded from unverified: C/F and 50 Hz agree across VDE and WorldStandards. ADAC confirms 230 V 50 Hz.

Corroborated

Sources

  1. ADAC (German automobile club) - destination facts (opens in a new tab)230 V, 50 Hz; no adapter needed for German plugs
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. VDE: Power supply and safety when travelling (opens in a new tab)Plug types, voltage and 50 Hz for listed European countries (German standards body)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)
  6. CENELEC EN 60038:2011 Standard voltages (catalogue preview) (opens in a new tab)Only 50 Hz is used for public AC systems in Europe; 230/400 V transition values (European standard)

Checked 9 Nov 2026

Plugs and sockets

Types
Type B, Type C, Type F
Most common
Type F
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Former Soviet standard; European outlets common.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type A
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Voltage: Also quoted as 110 V.

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type I
Most common
Type I
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older data gives 220 V.

Notes

Australian/NZ-style outlets.

Corroborated

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz

Voltage: Also quoted as 110 V.

Notes

US-style supply.

Corroborated

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
240 V
Frequency
50 Hz
Three-phase
415 V

Notes

BS 1363 (G). Pass 3: Third independent source agrees: type G, 240 V.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)240 V; earthed type G sockets
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Nominal changed from 220 V to 230 V (230/400 V, range 207-253 V) on 1 July 2025.

Notes

Schuko-type (F) generally reported; US government list shows only C. Pass 3: Upgraded from unverified: C/F corroborated (ANWB + WorldStandards); 230 V since July 2025 reported by utility via Interfax.

Corroborated

Sources

  1. Interfax-Ukraine - transition to 230 V (quoting Kharkivoblenergo and the regulator NEURC) (opens in a new tab)Nominal socket voltage now 230 V with permitted range 207-253 V, aligned with the European standard
  2. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)220 V (older figure); two-round-hole sockets, unearthed C or earthed F
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  4. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  5. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Abu Dhabi DoE: 230 V / 400 V. Other emirates' authorities not opened.

Notes

BS 1363 (G) approved; Schuko prohibited; Europlug only via adapter; BS 546 15 A not allowed in new domestic work. Field confidence - plugs: verified, voltage: verified, frequency: verified.

Verified

Sources

  1. Abu Dhabi DoE Electricity Wiring Regulations 2020 (opens in a new tab)230 V single-phase / 400 V three-phase, 50 Hz; BS 1363 approved, Schuko prohibited, BS 546 15 A not permitted in new domestic work
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: 230 V +10%/-6% by law (ESQCR reg. 27).

Frequency: 50 Hz ±1%.

Notes

BS 1363 (G) sockets. Field confidence - plugs: verified, voltage: verified, frequency: verified.

Verified

Sources

  1. Electricity Safety, Quality and Continuity Regulations 2002, reg. 27 (opens in a new tab)230 V +10%/-6% and 50 Hz ±1% for low-voltage supply (UK law)
  2. VDE: Power supply and safety when travelling (opens in a new tab)Plug types, voltage and 50 Hz for listed European countries (German standards body)
  3. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Yes, earthed sockets are standard

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
208 V

Voltage: Split-phase 120/240 V; 240 V for large appliances.

Notes

120/240 V split-phase to homes; commercial three-phase 120/208 V or 277/480 V.

Verified

Plugs and sockets

Types
Type C, Type F, Type I, Type L
Most common
Type F
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Mixed outlet types.

Corroborated

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Yes, earthed sockets are standard

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Some sources quote 230 V.

Notes

Former Soviet standard.

Corroborated

Plugs and sockets

Types
Type C, Type G, Type I
Most common
Type I
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older data gives 220 V.

Notes

Australian-style outlets with some European/British types.

Corroborated

Plugs and sockets

Types
Type C, Type F, Type L
Most common
Type L
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

Italian practice; only one source found. Pass 3: Upgraded: C/F/L and 230 V corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; type C, L and F sockets, combination sockets, 16 A type L for large appliances
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type A, Type B
Most common
Type B
Earthed
Not recorded

Supply

Voltage
120 V
Frequency
60 Hz
Three-phase
208 V

Notes

North American-style supply.

Corroborated

Plugs and sockets

Types
Type A, Type C
Most common
Type C
Earthed
Not recorded

Supply

Voltage
220 V
Frequency
50 Hz
Three-phase
380 V

Voltage: Commonly quoted as 220 V / 380 V; national distribution rules list 0.4 kV (i.e. 230/400 V) as the LV level. Treat as 220-230 V.

Notes

Combination outlets accepting flat and round pins are typical; earthing often absent. Pass 3: Third independent listing agrees on 220 V 50 Hz; VDE also lists type F. Frequency verified (MOIT Circular 39/2015: 50 Hz ±0.2 Hz); the circular lists 0.4 kV as the LV distribution level, consistent with 230/400 V, while 220/380 V is still widely quoted.

Corroborated

Sources

  1. VDE (German electrical engineering association and standards publisher) - power supply when travelling (opens in a new tab)Independent listing: Vietnam 220 V, 50 Hz, A/C/F
  2. MOIT Circular 39/2015/TT-BCT on the distribution system, ch. 2 sec. 1 (hethongphapluat.com text) (opens in a new tab)Art. 4: national nominal frequency 50 Hz (±0.2 Hz normal); Art. 5: nominal distribution voltages down to 0.4 kV; ±5% at customer connection points
  3. US International Trade Administration - Electric Current Worldwide (legacy.trade.gov, dated data c.2002) (opens in a new tab)Lists: 50 Hz, mainly 220/380 V (some 127/220 V legacy), A/B/C/E/F
  4. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, A/B/C

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type F
Most common
Type F
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Notes

French-style supply. Only one secondary source could be checked. Check local rules.

Check local rules

Sources

  1. WorldStandards - Plug, socket & voltage by country (opens in a new tab)Lists: 230 V, 50 Hz, C/E

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type G
Most common
Type G
Earthed
Not recorded

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Schneider gives 250/440 V; WorldStandards gives 230 V.

Notes

Universal sockets very common. Field confidence - plugs: unverified, voltage: unverified, frequency: corroborated. Check local rules.

Check local rules

Sources

  1. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  2. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  3. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Older sources give 220/380 V.

Notes

BS 1363 (G); older D/C also seen. Pass 3: Upgraded: G with C/D corroborated; 230 V corroborated (ANWB + WorldStandards).

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)230 V; mostly type G, also type C and occasionally type D
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

Plugs and sockets

Types
Type C, Type D, Type G
Most common
Type G
Earthed
Yes, earthed sockets are standard

Supply

Voltage
230 V
Frequency
50 Hz
Three-phase
400 V

Voltage: Quoted as 220 V by ANWB and older sources; nominal 220-230 V.

Notes

BS 1363 (G); older D also seen. Pass 3: Upgraded: plug list G/D/C corroborated; voltage 220-230 V.

Corroborated

Sources

  1. ANWB (Dutch travel/motoring association) - practical information on arrival (opens in a new tab)220 V; mostly type G, some type D, occasionally type C or universal
  2. WorldStandards: plug, socket and voltage by country (opens in a new tab)Plug types, single-phase voltage and frequency (technical reference compilation)
  3. US International Trade Administration: Electric Current Worldwide (opens in a new tab)Frequency, nominal voltages and plug types (US government compilation; older data, many voltages pre-date 230 V harmonisation)
  4. Schneider Electric Electrical Installation Guide: Low-voltage consumers (opens in a new tab)Frequency and LV single/three-phase voltages (technical guide; some figures pre-date harmonisation)

Checked 9 Nov 2026

No countries or territories match your search.

Check before you connect. Plug types, voltage and frequency shown are for normal domestic supplies. Hotels, older buildings and some territories may have other socket types. Confidence shows how well each entry is supported: Verified entries were confirmed from an authoritative source such as the IEC, a national standard, regulator or utility; Corroborated entries are supported by two independent technical sources; entries marked Check local rules show the best-known values and should be confirmed locally.

Plug types A to O. Know the shape.

Simplified front views of each plug, looking at the pins. Earth contacts are shown in orange. Select a type to filter the country list.

Earth pin, clip or socket earth hole · drawings are schematic and not to scale

Travelling from the UK? Adapter or converter.

UK sockets are Type G at 230 V, 50 Hz. Choose where you are going to see what your UK plugs and appliances need.

Plugs, voltage and frequency. Explained.

A plug adapter changes the shape, not the supply. These three ideas cover almost every question about using equipment abroad. For the conductors behind the socket, see wiring colour codes by country and how each country earths its supply; to size a converter, work out the load with the single-phase power calculator.

Why there are so many plug types

Countries electrified at different times and each wrote its own standard, so plug shapes grew up separately. The letters A to N are a simple naming system used to tell the families apart; they are not part of the standards themselves.

Some types are related. Type B is an earthed Type A, Type M is a larger Type D, and the two-pin Europlug (Type C) fits most round-pin sockets. A socket can also be built to take more than one type, so a country listing several letters does not always mean several kinds of outlet in every building.

An adapter only changes the shape. It does nothing to the voltage, and a plug that has an earth pin may lose its earth connection if the adapter or socket has none.

Voltage and frequency are different things

Voltage is the electrical pressure the supply provides. Most of the world uses 220–240 V; North America, much of Central America, Japan and a few others use 100–127 V. Plugging a 230 V-only appliance into a 120 V supply usually leaves it weak or not working; plugging a 120 V-only appliance into 230 V can destroy it within seconds.

Frequency is how many times per second the alternating current changes direction: 50 Hz or 60 Hz. It mainly matters to things with motors, transformers or timers. A mains clock or a motor designed for 50 Hz runs faster and warmer on 60 Hz, and the other way round it may run slow or overheat.

Japan is unusual in having both: 50 Hz in the east and 60 Hz in the west. The three-phase figure (for example 400 V) is the voltage between phases on commercial and industrial supplies.

Why dual-voltage appliances matter

Check the rating plate or the charger brick. If it says something like INPUT 100–240 V ~ 50/60 Hz, the appliance adjusts itself and only needs a plug adapter anywhere in the world. Phone, tablet and laptop chargers, camera chargers and many shavers are made this way.

Heating appliances such as hair dryers, straighteners, kettles and travel irons are often single-voltage. On a lower-voltage supply they need a step-up converter (a transformer) rated well above the appliance’s wattage, or a dual-voltage travel model. A switch on the appliance marked 115/230 must be set correctly before it is plugged in.

For site and trade work, never rely on an adapter for power tools or a site transformer. Use equipment built and certified for the local supply.

Secret Link