Why this matters

Buried electricity cables, gas pipes and water mains can kill or seriously injure if they are hit. HSE guidance says plans alone are not enough to find services, and the absence of records is never proof that the ground is clear. A safe system has three parts: plan the work, locate and identify services, and dig safely.

Key points

  1. Get and review plans of all buried services before work starts.
  2. Plans only show roughly where services are. Never take depths or distances from them.
  3. No plans does not mean no services. Dig as if services are there.
  4. Trace services with a cable locator (CAT) and signal generator (Genny) used by a trained person.
  5. Mark the line of services with crayon, chalk or paint. Re-check with the locator as you dig.
  6. Dig trial holes by hand to confirm the position and depth of a service.
  7. Site rule: powered digging stays 500 mm clear; agree any greater owner clearance.
  8. Treat every service as live until it is disconnected and proven safe at the point of work.

Do and don’t

Do

  • Dig alongside the service, not straight on top of it.
  • Expose services the last bit of the way by digging sideways, not down.
  • Use insulated tools when hand digging near electric cables.
  • Ease spades in with gentle foot pressure.
  • Treat any service you can't identify as a live electricity cable or gas pipe.

Don’t

  • Don't rely on plans or colour alone to tell you what a service is.
  • Don't throw or spike a spade into the ground near services.
  • Don't use picks in soft clay or soft soils near services.
  • Don't use a mechanical excavator within 500 mm of a gas pipe.
  • Don't drive stakes or pins directly above marked services.

Ask the group

  • What plans do we have for this dig, and who has checked them against the locator survey?
  • Who on this team is trained to use the CAT and Genny, and when was it last checked?
  • What would you do if you found a service that isn't on the plans?
  • What are the colour codes for UK services, and why can't we trust them on their own?

If it goes wrong

After a cable strike, stay in the cab, keep others away and contact the network operator. Call 999 for injury or fire. For a gas escape, move clear and avoid ignition sources. Call 0800 111 999 (GB) or 0800 002 001 (NI) from safety.

Quick check

Five questions to check the talk landed. Ask them out loud, then show the answers.

1. There are no service records for the area. What should you assume?
  1. There are no services
  2. Services could be there, so dig as if they are
  3. Only water pipes are present

Answer: Services could be there, so dig as if they are. HSE says the absence of records is never proof the area is free of services.

2. What is the minimum powered-digging clearance in this talk’s site rule?
  1. No closer than 500 mm
  2. No closer than 100 mm
  3. Right on top if you are careful

Answer: No closer than 500 mm. This talk uses a conservative site rule. HSG47 has task-specific 500 mm guidance and exceptions; agree the method and owner requirements.

3. When is a buried service safe to treat as dead?
  1. When it looks old
  2. When the plans say it's abandoned
  3. When it is disconnected and proven safe at the point of work

Answer: When it is disconnected and proven safe at the point of work. HSE says assume all services are live until disconnected and proven safe at the point of work.

4. Where should you dig in relation to a located service?
  1. Directly above it
  2. Alongside it
  3. It doesn't matter

Answer: Alongside it. HSE says excavate alongside the service rather than directly above it.

5. You smell gas after hitting a pipe. What do you do first?
  1. Try to tape it up
  2. Carry on and report it later
  3. Get everyone away and call the gas emergency number 0800 111 999

Answer: Get everyone away and call the gas emergency number 0800 111 999. HSG47 says do not attempt repairs, evacuate the area and call 0800 111 999.

Running this talk on site?The PDF has a sign-in sheet for your safety file and a poster for the welfare cabin.

Download free PDF

Go further

Underground utility colour codes ›

Sources and qualifications

Source review: 25 November 2026. GB legislation unless another nation is identified. Environmental record periods are for England; check the rules for the site location.

A4 interface: locating/protecting existing cables and correct isolation. The 500 mm site rule is not an A4 burial-depth requirement. HSG47 and the service owner govern the excavation method.

A4 basis: published IET guidance; the full licensed standard was not available for clause-by-clause checking. This is a source review, not installation certification. IET current edition.