Plug-in solar in Great Britain: what electricians need to know

Plug-in solar panels mounted on a flat balcony

A specific route for compliant plug-in solar devices took effect in Great Britain on 27 August 2026. Customers will be asking about them, and the rules differ from a conventional PV install.

The limits

Under the new regulations (SI 2026/848), a compliant kit can connect through a standard socket. The statutory device definition caps rated output at 800W AC. The final interim product specification also limits apparent power to 800VA and current to 3.5A, with up to 2,000W of PV modules. Manufacturers must advise consumers installing more than 960W of modules to consider professional assessment of their existing electrical installation. Kits must meet the government’s Plug-in Solar Device Interim Product Specification and appear on the ENA G98 type test register. The plug must be a BS 1363-1 plug going straight into a fixed socket. Extension leads and adaptors are not allowed, and plug-in batteries and solar-plus-battery kits remain excluded.

The network side

Ofgem approved a change to the G98 distribution code on 11 August 2026. It allows one plug-in microgenerator per customer installation, which is stricter than the product specification’s one per final circuit. A plug-in unit can sit alongside a permanently wired PV system as long as the combined output stays within the 16A per phase G98 limit; above that, G99 applies. Households must notify their DNO within 28 days using a simplified form.

Where electricians come in

Self-connection does not need an electrician, but Ofgem notes that its exemptions do not remove BS 7671 or other safety requirements. The circuit a kit plugs into still matters. Expect requests to check sockets and circuits, to add an existing PV system to the 16A calculation, or to fit a kit professionally for customers who would rather not do it themselves.

Related guide: How Do Solar Panels Work?

Sources: Ofgem decision on DCRP MP 26/02, 11 August 2026; GOV.UK: Plug-in solar consultation and response; Fuse Energy: what changed on 27 August 2026.

Photo: Yuma Solar / Unsplash

Share article

Was this article helpful?

Real, sourced news for the UK trades.

Plug-in solar in Great Britain: what electricians need to know