Tradefox app icon: crossed hammer and saw on an orange background

Tradefox – Build Skills

Learn Construction

Weather for the trades

Today27 Nov
4° / 2°4.1mm rain22mph gusts
Below 3°CShowers
NHBC: masonry should not be built below 3°C and falling. Drying times extended; plan wet trades indoors.
Sat28 Nov
10° / 4°6.3mm rain29mph gusts
Wet
External render, painting and roofing likely off.
Sun29 Nov
9° / 5°0.0mm rain20mph gusts
Workable
No cold, wet or wind flags on the forecast.
Mon30 Nov
12° / 7°2.1mm rain35mph gusts
ShowersGusts 35mph
Drying times extended; plan wet trades indoors. Check against your stop-work limits before any work at height.
Tue1 Dec
13° / 9°2.4mm rain36mph gusts
ShowersGusts 36mph
Drying times extended; plan wet trades indoors. Check against your stop-work limits before any work at height.
Wed2 Dec
9° / 5°1.2mm rain22mph gusts
Showers
Drying times extended; plan wet trades indoors.
Thu3 Dec
7° / 4°0.0mm rain18mph gusts
Workable
No cold, wet or wind flags on the forecast.

Forecast from Open-Meteo, refreshed through the day. Figures are for Birmingham and will differ across a region and at height.

What the numbers mean on site

Bricklaying, rendering and screeds

NHBC Standards say brickwork and blockwork should not be built when the air temperature is below 3°C and falling. The Mortar Industry Association says masonry construction should stop below 3°C unless the mortar is held at a minimum of 4°C until it has hardened, for example in a heated enclosure. Freshly laid mortar can fail if it freezes, so cover materials and new work.

Roofing, scaffolding and work at height

There is no single legal wind limit for work at height: it depends on the equipment, and gusts matter more than averages. NHBC advises setting your own wind and gust limits for scaffolds and roofs, stopping when they are exceeded, and checking conditions with an anemometer at the workplace rather than relying on a forecast alone. For roof work, HSE guidance HSG33 covers wind speeds. Cranes have a manufacturer maximum design wind speed and must be taken out of service above it.

Painting, decorating and external coatings

Rain and damp hold moisture in substrates and extend drying and curing times. Minimum application temperatures and humidity limits vary by product, so check the manufacturer data sheet for what you are using rather than a general rule.

Groundworks and concrete

Frost affects pours, screeds and curing. Protect fresh work overnight, and allow for wet ground slowing excavation and site access.

This page reports forecast conditions and the published thresholds that go with them. It is not a risk assessment and does not say whether work is safe. There is no legal minimum or maximum temperature for working outdoors; the decision stays with the duty holder under your own RAMS.