Technical guidance published · 2026-11-17
The British Woodworking Federation has issued new guidance on simulated glazing bars, highlighting the choices behind timber windows designed to reproduce traditional proportions with modern double glazing. Published on 17 November, the technical article by Kevin Underwood examines the differences between bars within a sealed unit and mouldings attached to its faces.
The BWF explains that bars inside the glazing cavity affect the window U-value. Its account of BS EN 14351-1 gives additions of 0.1 W/m²K for one internal bar and 0.2 W/m²K for multiple bars, compared with 0.4 W/m²K for traditional glazing bars. Applied face bars have no effect under the cited method. These are adjustments described in the guidance, rather than complete window ratings.
Appearance and performance can also meet the separate demands of heritage work. In an earlier BWF case study, an inspector allowed replacement windows at a Grade II listed property after finding that existing modern joinery did not contribute to its significance. The federation advises that individual cases require individual assessment. That account concerns a particular appeal and does not establish a general permission to replace historic windows.
For joinery businesses, the practical question is how a proposed bar arrangement fits the actual order. A useful quotation should identify the glazing construction, visible profile and performance evidence together, so that a customer can see what is being priced. A photograph of a traditional window alone leaves too much scope for different interpretations. A sample corner or glazing detail may make the specification easier to agree.
The publication also gives manufacturers a reason to review installation instructions alongside sales descriptions. Where the work involves a listed building, the specific consent and approved drawings should shape the final product. Agreeing that detail before manufacture can help avoid a late argument over a window that looks broadly right but differs from the required construction.
Sources · BWF simulated glazing bars · BWF heritage joinery case study
Glazing bars and U-value adjustments. BWF account of BS EN 14351-1 Annex J. Adjustments, not whole-window ratings. Image credit: TradeFox Newsdesk / original illustration · CC0-1.0 for original graphic elements; factual data attributed to linked primary sources. No third-party photographs or logos used..
Share article
Was this article helpful?
Thanks — that helps us improve these guides.