Why this matters

Power tools and abrasive wheels cause serious cuts, eye injuries and electric shocks. A disc spun faster than it's rated for can burst, and cutting stone or concrete makes harmful silica dust.

Key points

  1. Only someone properly trained and appointed should fit or change an abrasive wheel or disc.
  2. Check the disc's maximum speed. It must be at least the tool's spindle speed, never less.
  3. Keep the guard on and adjusted so only the part of the disc you need is exposed.
  4. Check discs for damage before use. Don't use a chipped or cracked disc.
  5. Before using any tool, check the plug, cable and casing. No tape repairs or bare wires.
  6. A single-phase 110 V centre-tapped-to-earth supply has 55 V from either live conductor to earth. Reduced voltage lowers, but does not remove, shock risk.
  7. Cutting stone, concrete and blocks needs water suppression or on-tool extraction, plus a suitable mask.
  8. Wear eye protection, avoid loose clothing and jewellery, and tie back long hair.

Do and don’t

Do

  • Check the tool and lead before every use, and report faults.
  • Use the right disc for the material and the tool.
  • Switch off and unplug before changing discs, bits or blades.
  • Test plug-in RCDs with the test button before each use.
  • Store discs somewhere dry, where they can't roll or fall.

Don’t

  • Don't remove or tie back the guard to get a better cut.
  • Don't fit a disc unless you're trained and appointed to do it.
  • Don't use a tool with a damaged plug, cable or casing.
  • Don't bypass an RCD that keeps tripping. Get the fault found.
  • Don't dry-cut stone or concrete without dust controls.

Ask the group

  • Who on this site is trained and appointed to change discs?
  • Where do we get our tools and leads checked, and how often?
  • What dust controls do we use when cutting blocks or kerbs?
  • Have you seen a guard removed or a tape-repaired lead this week?

If it goes wrong

If a disc bursts or someone is cut, switch off and unplug the tool, call 999 for serious injuries and get a first aider. If someone gets an electric shock, switch off the supply before touching them. Keep the tool and disc aside for checking and tell your supervisor.

Quick check

1. Who should fit or change an abrasive wheel?
  1. Anyone who uses the grinder
  2. Someone properly trained and appointed
  3. The apprentice

Answer: Someone properly trained and appointed. Abrasive wheels must be mounted by someone who has been properly trained and appointed to do it.

2. How should the disc's maximum speed compare with the tool's speed?
  1. It can be lower
  2. It must be at least the tool's spindle speed
  3. It doesn't matter

Answer: It must be at least the tool's spindle speed. The spindle speed must never exceed the maximum speed marked on the wheel, or it could burst.

3. What does a 110 V centre-tapped transformer do?
  1. 55 V from each live conductor to earth
  2. Makes tools faster
  3. Stops dust

Answer: 55 V from each live conductor to earth. For a single-phase 110 V centre-tapped supply, each live conductor is 55 V to earth. The risk of electric shock remains.

4. What should you use when cutting concrete with a cut-off saw?
  1. Nothing if it's a quick cut
  2. Water suppression or on-tool extraction, plus a suitable mask
  3. A dust sheet

Answer: Water suppression or on-tool extraction, plus a suitable mask. HSE advises water suppression or on-tool extraction, with RPE such as an FFP3 mask as back-up.

5. An RCD keeps tripping. What do you do?
  1. Bypass it
  2. Stop and get the fault checked
  3. Use a different socket and carry on

Answer: Stop and get the fault checked. Never bypass an RCD. If it trips, the system should be checked for a fault before it's used again.

Running this talk on site?Download the talk, attendance register, quick check and posters.

Download free PDF

Sources and qualifications

Source review: 25 November 2026. GB legislation unless another nation is identified. Environmental record periods are for England; check the rules for the site location.

A4 interface: equipment supply/protection and correct isolation. Single-phase 110 V centre-tapped-to-earth is 55 V to earth. The current standard and site design govern the actual installation.

A4 basis: published IET guidance; the full licensed standard was not available for clause-by-clause checking. This is a source review, not installation certification. IET current edition.

This talk supports, but does not replace, your site-specific risk assessment, method statement, training and supervision. Free to download, print and share.