Leaning ladder 1 in 4 rule: base distance, ladder length and angle
- where
- distance of the ladder foot out from the wall (m)
- height from the ground to the top resting point (m)
- ladder length from the foot to the resting point (m)
- minimum ladder length including the extension (m)
- height the ladder must rise above the resting point, measured vertically (m)
- ladder angle to the ground (°)
Explain this equation
Sets up a leaning ladder by the HSE 1 in 4 rule: how far the foot goes out from the wall, how long the ladder needs to be, and the angle it ends up at. Use it before you pick a ladder for a job or set one up against a scaffold or roof edge.
H is the vertical height from the ground to where the ladder rests. The 1 in 4 rule puts the foot one unit out for every four up, so b = H/4. The ladder is the sloping side of a right-angled triangle with sides H and b, so Pythagoras gives its length L_s. E is how far the ladder must rise above the resting point, measured vertically: at least 1 m where it is used to reach another level. Because the slope stays at 1 in 4, the full ladder is L_s scaled up by (H + E)/H. arctan of H/b, which is always 4, gives the angle.
The wall, the ground and the ladder form a right-angled triangle, so the length comes from Pythagoras and the angle from its rise over run.
Sense check: a ladder resting 4 m up goes 1 m out and is about 4.12 m long to the wall. To rise a further 1 m it needs about 5.15 m in all, a little more than 4.12 + 1 because the extra metre is on the slope. The angle is always 76°, which is the 75° the guidance quotes.
Watch out: measure H vertically to the resting point, not along the ladder, and measure the 1 in 4 from the wall at ground level. Extension ladders lose length in the section overlap.
Sets up a leaning ladder by the 1 in 4 rule: how far the foot goes out from the wall, how long the ladder must be to reach the resting point and extend above it, and the angle that gives.
Enter your values to see the result.
Good to know
HSE guidance is to set a leaning ladder at 75° using the 1 in 4 rule: one unit out for every four units up. Strictly, 1 in 4 gives 75.96°, which is the 75° the guidance means. H is measured vertically from the ground to where the ladder rests on the wall. A ladder used to reach another level (a scaffold lift or a roof) should be tied and extend at least 1 m above the landing point to give a handhold; when working from a ladder, try to keep at least 1 m (three rungs) above where you are working and do not work off the top three rungs. E is that height measured vertically, as HSE states it; because the ladder leans, it needs about 1.03 m of ladder along the stiles for every 1 m of rise, which the calculator includes. Secure the ladder by tying, then a stability device, then wedging; footing is the last resort.
Common mistake
Measuring the distance out from the top of the ladder or along the stiles instead of from the wall at ground level, or forgetting the 1 m extension and buying a ladder that only just reaches.
Limits
Leaning ladders on firm, level ground against a strong upper resting point. Ladders are for short-duration, light work; use a tower or scaffold for longer tasks. Extension ladders need extra length for the section overlap set by the manufacturer.
Sources
- HSE INDG455 Safe use of ladders and stepladders: a brief guide (ladder angle 75°, use the 1 in 4 rule, 1 unit out for every 4 units up; extend at least 1 m (three rungs) above where you are working; do not work off the top three rungs)
- Ladder Association LA455 Safe use of ladders and stepladders, produced with HSE (75°, 1-in-4 rule; ladders used to reach another level extend at least 1 m above the landing point)
- HSE, Securing ladders and ladders used for access (ladders used to access another level should be tied and extend at least 1 m above the landing point; footing is the last resort)
Results are calculations from the published methods and figures shown, and depend on the data you enter. For planning and checking only. Scaffolds must be erected to NASC TG20 or a bespoke design by competent persons, and lifting operations planned under LOLER by a competent person. Never rely on these results instead of a design, a lift plan or manufacturer ratings.