DC cabling

DC string cable voltage drop

Rt=R20(1+0.00393(θ−20))Vd=2LIRt1000p=100VdVP=VdI
where
Rt
conductor resistance at operating temperature (Ω/km)
R20
conductor resistance at 20 °C (Ω/km)
θ
conductor operating temperature (°C)
Vd
voltage drop (V)
L
cable route length, one way (m)
I
string operating current (A)
p
voltage drop as a percentage (%)
V
string voltage at maximum power (V)
P
power lost in the cable (W)
Explain this equation

Works out the voltage drop and power loss in the DC cable between a PV string and the inverter. Use it to choose a cable size that keeps losses low.

Copper resistance rises with temperature by about 0.393% per degree, which corrects the 20 °C table value to the working temperature. Current goes out and back, so the length is doubled. Resistance is per kilometre, so the 1000 converts to metres. Drop is current times resistance; as a percentage it is compared with the string voltage. Drop times current gives the watts turned into heat.

Ohm's law on a two-wire run, with the usual temperature correction for copper.

Sense check: 20 m of 4 mm² at 13 A and 70 °C drops about 3.2 V, under 1% of a 400 V string, losing about 41 W.

Watch out: use the resistance for the actual conductor (tinned, class 5 PV cable is slightly higher than plain copper) and the one-way route length.

Voltage drop and power loss in the positive and negative cables of a PV string between the array and the inverter.

Ω/km
°C

Enter your values to see the result.

Good to know

The 2 accounts for the go and return conductors. PV cable uses fine-stranded tinned copper (class 5), whose resistance is higher than plain solid copper: about 8.21, 5.09, 3.39 and 1.95 Ω/km at 20 °C for 2.5, 4, 6 and 10 mm². Copper resistance rises by 0.393% per °C. Use Imp and Vmp at STC for the design check. MIS 3002 says 1% is practicable for domestic AC cabling; aim for the same on DC.

Common mistake

Using the one-way length without the factor of 2, or the 20 °C resistance for cable that runs hot behind modules.

Limits

Resistive drop only; DC has no reactance. Ignores connector resistance. Use the cable maker's declared resistance where available.