Array size from panel count

Ppk=NWp1000
where
Ppk
array peak power (kWp)
N
number of modules
Wp
module STC rating (W)
Explain this equation

Works out the peak power of an array from the number of panels and their rating.

Each module is rated in watts at Standard Test Conditions (1000 W/m² of sunlight at 25 °C cell temperature). Adding them, N × W_p, gives watts peak; dividing by 1000 gives kWp, the unit used for yield estimates and DNO forms.

Simple multiplication of number by rating.

Sense check: ten 430 W panels is 4.3 kWp.

Watch out: kWp is a rating, not what the array delivers on a typical day. Inverter output is usually lower than the array peak.

Total DC peak power of an array, the kWp figure used in the MCS yield estimate, the DNO notification and the inverter ratio.

modules

Enter your values to see the result.

Good to know

Use the nameplate Pmax at STC (1000 W/m², 25 °C cell, AM1.5) from the module datasheet. Mixed module types: add each group separately.

Common mistake

Using the inverter AC rating or a rounded marketing figure instead of the exact datasheet Pmax of the modules fitted.

Limits

STC rating only. Real output is lower most of the time because of temperature, irradiance and losses.