Thermal resistance and U-values

Thermal resistance of a layer (R = d / λ)

R=d1000λ
where
R
thermal resistance of the layer (m²K/W)
d
layer thickness (mm)
λ
thermal conductivity (W/mK)
Explain this equation

Works out how much a single layer of material resists heat flow. It is the building block of every U-value calculation.

λ (lambda) is how readily the material conducts heat: low for insulation, high for brick, concrete and metal. A thicker layer resists more, so resistance is thickness divided by λ. The thickness is entered in millimetres, so the 1000 converts it to metres. The calculator also shows 1/R, the U-value the layer would have on its own.

Heat conduction through a slab is proportional to λ and inversely proportional to thickness, so resistance is d/λ.

Sense check: 100 mm of PIR at 0.022 gives about 4.5 m²K/W; the same thickness of brick at 0.77 gives only 0.13.

Watch out: use the declared or design λ for the actual product, not a generic figure. Thin, high-λ layers such as plaster add very little.

Works out the thermal resistance of one uniform layer of insulation, board or masonry from its thickness and thermal conductivity.

W/mK

Enter your values to see the result.

Good to know

Use the manufacturer's declared λ (the λD on the data sheet or the DoP) for insulation, and BS EN ISO 10456 design values for masonry, timber and plaster. Typical λ: foil-faced PIR about 0.022, phenolic 0.018–0.020, mineral wool loft roll 0.044 (Knauf Loft Roll 44), EPS 0.030–0.038, softwood 0.13, brick 0.77, plasterboard 0.19–0.25 W/mK. Many board data sheets also quote R directly, rounded down to 0.05 m²K/W.

Common mistake

Entering thickness in metres, or using an old or generic λ when the product on site has a different declared value. Halving λ doubles R just as surely as doubling thickness.

Limits

One homogeneous layer, steady one-dimensional heat flow. Not valid for air layers (use the BS EN ISO 6946 air-layer tables) or for layers bridged by timber or steel (use the bridged-layer calculator).

Sources