Convert air changes n50 to air permeability q50

q50=n50VAE
where
q50
air permeability at 50 Pa (m³/(h·m²))
n50
air changes per hour at 50 Pa
V
internal volume (m³)
AE
envelope area (m²)
Explain this equation

Converts air changes at 50 Pa (n50) into air permeability (q50), the figure used in UK Building Regulations and SAP.

n50 times the volume gives the leakage in m³/h; dividing by the envelope area gives leakage per square metre of envelope.

The reverse of the q50 to n50 conversion.

Sense check: 3 air changes in a 300 m³ house with 250 m² of envelope is 3.6 m³/(h·m²).

Watch out: Passivhaus 0.6 n50 targets are far tighter than typical UK q50 values; compare like with like.

Converts an air change rate at 50 Pa into the UK air permeability figure used by Building Regulations and SAP.

h⁻¹
m³
m²

Enter your values to see the result.

Good to know

Useful when a target is set in n50 (for example EnerPHit 1.0 h⁻¹ or Passivhaus 0.6 h⁻¹) and you need the equivalent q50 for the SAP or PAS 2035 paperwork.

Common mistake

Using external volume. V is the internal heated volume the test is based on.

Limits

Relies on the same AE and V the tester used.