Quantities
Block quantity
- where
- blocks per square metre
- block length (mm)
- perpend joint (mm)
- block height (mm)
- bed joint (mm)
- net area (m²)
- waste allowance (%)
Explain this equation
This estimates how many blocks to order for an area of blockwork, including waste.
l and h are the block's face length and height in mm. j_p and j_b are the perpend and bed joints. Each block with its joints covers (l + j_p) × (h + j_b) of wall face, and N_m² is how many of those fit in one square metre. A is the net area and w the waste percentage.
There are 1 000 000 mm² in a square metre, so dividing by the face area of one block plus its joints gives the rate per m². A × N_m² is the net number, (1 + w/100) adds waste, and the ⌈ ⌉ brackets round up to whole blocks.
A 440 × 215 mm block with 10 mm joints covers 450 × 225 mm, about 9.9 blocks per m², usually taken as 10. Ten square metres with 5% waste needs 104 blocks.
Watch out: thin-joint systems use joints of only a few millimetres, so enter the manufacturer's figures rather than ordinary 10 mm joints.
Estimate blocks from the chosen face size and joint widths.
Enter your values to see the result.
Good to know
Example is a 440 × 215 mm block with 10 mm joints. Enter manufacturer values for thin-joint systems; do not assume ordinary mortar dimensions.
Sources
Estimates are not design approval or British Standards compliance checks. Structural arch, retaining-wall, wind, foundation, lintel and masonry-capacity design are not performed. Use the project engineer’s specification.
Worked example
The inner leaf of an extension comes to 31.4 m² net of openings in standard 440 × 215 mm blocks with 10 mm joints, and with plenty of cuts around windows a 7% waste allowance is used. N = 1 000 000 ÷ (450 × 225) ≈ 9.88 per m², 31.4 × 9.88 ≈ 310 net, and ⌈310 × 1.07⌉ = 332 blocks. Round up to whole packs when you order, and keep the spares for making good.
Common questions
Do dense, medium and aircrete blocks give different counts?
No, not if their face size is the same, because the count only depends on face size and joints. They differ in weight, strength and thermal performance, which affect the choice of block, handling and delivery, not the number.
How should I count blocks laid flat?
If blocks are laid on their side, for example for a wider wall, the face showing is 440 × 100 or similar, not 440 × 215. Enter the face dimensions as laid and the count will be much higher.
Is 5% waste enough for blockwork?
For long plain walls it often is. Walls with many openings, short returns and lots of cutting around joists or services can need more, so adjust it to the job.