Tradefox Reference
Data and fibre colours.Pins, pairs, tubes and jackets.
The colour codes behind network, telephone and fibre cabling: T568A and T568B pinouts, crossovers and PoE, the 25-pair telephone code, UK BT socket colours and the TIA-598 fibre, jacket and connector colours. Every section lists its sources and how well they agree.
Twisted pair. T568A and T568B.
Both schemes use the same four colour pairs on the same RJ45 plug. The only difference is that the orange and green pairs swap places. Pick one scheme and use it at both ends of every link.
All eight conductors are terminated on every outlet and patch lead, whatever speed the link runs at.
- Pair 1
- Blue, pins 4 and 5
- Pair 2
- Orange
- Pair 3
- Green
- Pair 4
- Brown, pins 7 and 8
Swipe the table sideways to see every column.
| Pin | T568A | T568B | 10/100 | Gigabit and faster | PoE |
|---|---|---|---|---|---|
| 1 | White/greenPair 3 | White/orangePair 2 | Transmit + | Data, both directions | Alt A (data pair) |
| 2 | GreenPair 3 | OrangePair 2 | Transmit − | Data, both directions | Alt A (data pair) |
| 3 | White/orangePair 2 | White/greenPair 3 | Receive + | Data, both directions | Alt A (data pair) |
| 4 | BluePair 1 | BluePair 1 | Not used | Data, both directions | Alt B (spare pair at 10/100) |
| 5 | White/bluePair 1 | White/bluePair 1 | Not used | Data, both directions | Alt B (spare pair at 10/100) |
| 6 | OrangePair 2 | GreenPair 3 | Receive − | Data, both directions | Alt A (data pair) |
| 7 | White/brownPair 4 | White/brownPair 4 | Not used | Data, both directions | Alt B (spare pair at 10/100) |
| 8 | BrownPair 4 | BrownPair 4 | Not used | Data, both directions | Alt B (spare pair at 10/100) |
T568A and T568B pin colours
Verified
Pin colour assignments agree across a university IT standard page, a UK distributor and Intel.
- Nebraska Wesleyan University IT Support: Cabling Color Codes (opens in a new tab)T568A and T568B pin 1 to 8 colours; 25-pair major and minor colour sequence and tip/ring
- Rapid Electronics: Ethernet cable colour codes (opens in a new tab)T568A and T568B pin colours, pin 1 orientation, A-to-B crossover, T568B common in UK commercial work
- Intel Support: Ethernet cable pinouts (article 000007187) (opens in a new tab)10/100 uses pins 1, 2, 3 and 6; crossover 1-3 and 2-6; gigabit crossover adds 4-7 and 5-8
- Fluke Networks: Wire map testing, it is not all about colour (opens in a new tab)T568A puts orange on pins 3-6, T568B puts green there; mixing schemes causes crossed pairs
- Fiber Optic Association: Uncle Ted's guide to UTP termination (opens in a new tab)A and B differ only by swapping pairs 2 and 3; pair colours; crossovers not needed at 1G and above
Checked 9 Nov 2026
Pairs used by 10/100, gigabit and crossovers
Verified
Pin functions from Cisco and Intel documentation.
- Cisco: Ethernet 10BASE-T and 100BASE-TX pinouts (document 46792) (opens in a new tab)Transmit on pins 1 and 2, receive on 3 and 6; pins 4, 5, 7, 8 unused by 10BASE-T
- Intel Support: Ethernet cable pinouts (article 000007187) (opens in a new tab)10/100 uses pins 1, 2, 3 and 6; crossover 1-3 and 2-6; gigabit crossover adds 4-7 and 5-8
- Fiber Optic Association: Uncle Ted's guide to UTP termination (opens in a new tab)A and B differ only by swapping pairs 2 and 3; pair colours; crossovers not needed at 1G and above
Checked 9 Nov 2026
Which pairs carry what.
Older and slower links only use two pairs; gigabit and faster use all four in both directions. Power over Ethernet rides on top of the data.
10BASE-T and 100BASE-TX
Pins 1, 2, 3, 6A device transmits on pins 1 and 2 and receives on pins 3 and 6. Pins 4, 5, 7 and 8 carry no data, but they should still be terminated so the cable works at higher speeds later.
Gigabit and faster
All 8 pins1000BASE-T and the multi-gigabit and 10G versions send and receive on all four pairs at once. A single swapped, split or open conductor will drop a gigabit link back to 100 Mb/s or stop it working.
Power over Ethernet
Alt A or Alt B- Alternative A: power on the data pairs (pins 1, 2 and 3, 6)
- Alternative B: power on pins 4, 5 and 7, 8
- 802.3af (Type 1) up to 15.4 W and 802.3at (Type 2) up to 30 W use two pairs
- 802.3bt Type 3 (60 W) and Type 4 (90 W) use all four pairs
Figures are the most the switch can supply. The device gets less once cable losses are taken off.
Power over Ethernet pairs and power
Corroborated
Power figures are the maximum at the switch (PSE); the device receives less after cable losses.
- Cisco: What is Power over Ethernet (PoE)? (opens in a new tab)802.3af/at/bt names and power levels; power on data pairs or spare pairs
- Microchip Developer Help: PoE terminology (opens in a new tab)PoE Types 1 to 4 (15.4, 30, 60, 90 W at the PSE), Alternative A and B pins, four-pair classes
- Linux kernel documentation: PSE power interface (opens in a new tab)Alternative A on pins 1, 2, 3, 6; Alternative B on 4, 5, 7, 8; spare pairs carry data at 1G and above
- Siemon: ANSI/TIA-568.2-E released (opens in a new tab)ANSI/TIA-568.2-E (2024) is the balanced twisted-pair standard; power delivery guidance added
Checked 9 Nov 2026
Crossover builder. See what each end does.
Choose how each end of a cable is terminated. The wire map shows where every conductor lands, just like a cable tester. Lines that change pin number are crossed.
Both ends use the same scheme, so every pin connects to the same pin at the far end. This is a normal patch lead or permanent link.
1→1, 2→2, 3→3, 4→4, 5→5, 6→6, 7→7, 8→8
Do you still need a crossover?
Almost never. Ports with auto MDI-X, which includes practically every gigabit port, sort out transmit and receive themselves. Use straight-through cables everywhere unless an old 10/100 device without auto MDI-X refuses to link.
A at one end, B at the other
This swaps the orange and green pairs: a 10/100 crossover. On a fixed link it is usually a mistake, made when two installers used different schemes. Testers report it as crossed pairs.
Full gigabit crossover
A true four-pair crossover also swaps blue with brown (pins 4 and 7, 5 and 8). It exists for old gigabit kit without auto MDI-X and is rarely made today.
The standards. Who says what.
Pin colours come from the North American TIA standard, but the same A and B layouts are used under the international and European cabling standards.
ANSI/TIA-568
The North American series that defines the T568A and T568B pin and pair assignments. The balanced twisted-pair part, ANSI/TIA-568.2, reached edition E in 2024 and now includes guidance on carrying power over data cabling.
ISO/IEC 11801
The international generic cabling standard for customer premises. Part 1 (2017) sets the common requirements for multi-vendor cabling that carries voice, data, video and power. It uses cabling classes rather than US category names.
EN 50173 and EN 50174
The European series, published in the UK as BS EN 50173. It covers generic balanced copper and optical fibre cabling for premises. Installation practice, including separation from power, sits in EN 50174-2.
IEC 60304
An older IEC standard that sets a palette of insulation colours for low-frequency telecoms cables and wires. It defines the colours themselves, not which conductor goes on which pin.
TIA-568, ISO/IEC 11801 and EN 50173
Verified
Standards summaries are taken from standards-body catalogue pages; the standards themselves are paid documents.
- Siemon: ANSI/TIA-568.2-E released (opens in a new tab)ANSI/TIA-568.2-E (2024) is the balanced twisted-pair standard; power delivery guidance added
- IEC Webstore: ISO/IEC 11801-1:2017 Generic cabling for customer premises (opens in a new tab)Title, edition and scope of ISO/IEC 11801-1
- iTeh Standards: EN 50173-1:2018 Generic cabling systems (opens in a new tab)EN 50173-1:2018 approved by CENELEC in 2018, replacing the 2011 edition
- BSI Knowledge: BS EN 50173-1 Generic cabling systems (opens in a new tab)EN 50173-1 covers balanced and optical fibre generic cabling for premises
Checked 9 Nov 2026
IEC 60304 standard insulation colours
Verified
IEC 60304 defines a palette of insulation colours for low-frequency cables; it does not set pinouts.
- IEC Webstore: IEC 60304:1982 Standard colours for insulation for low-frequency cables and wires (opens in a new tab)Title, edition 3.0 (1982) and scope of IEC 60304
Checked 9 Nov 2026
25-pair code. Five by five.
Multi-pair telephone cable uses five major colours and five minor colours. Each major colour runs through all five minors before the next major starts, giving 25 unique pairs. The tip wire is the major colour banded with the minor; the ring wire is the minor colour banded with the major.
- 1White/Blue
- 2White/Orange
- 3White/Green
- 4White/Brown
- 5White/Slate
- 6Red/Blue
- 7Red/Orange
- 8Red/Green
- 9Red/Brown
- 10Red/Slate
- 11Black/Blue
- 12Black/Orange
- 13Black/Green
- 14Black/Brown
- 15Black/Slate
- 16Yellow/Blue
- 17Yellow/Orange
- 18Yellow/Green
- 19Yellow/Brown
- 20Yellow/Slate
- 21Violet/Blue
- 22Violet/Orange
- 23Violet/Green
- 24Violet/Brown
- 25Violet/Slate
Top wire: tip (major colour, minor bands)Bottom wire: ring (minor colour, major bands)
Major (tip) colours
White, red, black, yellow, violet. Pairs 1–5 are white, 6–10 red, 11–15 black, 16–20 yellow and 21–25 violet.
Minor (ring) colours
Blue, orange, green, brown, slate, always in that order. The first four are the same pair colours used in Ethernet cable.
Binder groups
Bigger cables are built from 25-pair units, each wrapped in a binder ribbon or thread coloured in the same sequence: white/blue for pairs 1–25, white/orange for 26–50, and so on. Pair colours restart in every binder. 24 binders cover 600 pairs; larger cables add super-unit binders.
| Group | Binder colour | Pairs |
|---|---|---|
| 1 | White/Blue | 1–25 |
| 2 | White/Orange | 26–50 |
| 3 | White/Green | 51–75 |
| 4 | White/Brown | 76–100 |
| 5 | White/Slate | 101–125 |
| 6 | Red/Blue | 126–150 |
| 7 | Red/Orange | 151–175 |
| 8 | Red/Green | 176–200 |
| 9 | Red/Brown | 201–225 |
| 10 | Red/Slate | 226–250 |
| 11 | Black/Blue | 251–275 |
| 12 | Black/Orange | 276–300 |
| 13 | Black/Green | 301–325 |
| 14 | Black/Brown | 326–350 |
| 15 | Black/Slate | 351–375 |
| 16 | Yellow/Blue | 376–400 |
| 17 | Yellow/Orange | 401–425 |
| 18 | Yellow/Green | 426–450 |
| 19 | Yellow/Brown | 451–475 |
| 20 | Yellow/Slate | 476–500 |
| 21 | Violet/Blue | 501–525 |
| 22 | Violet/Orange | 526–550 |
| 23 | Violet/Green | 551–575 |
| 24 | Violet/Brown | 576–600 |
25-pair colour code
Verified
The same five major and five minor colours are used by telephone cable makers worldwide.
- Nebraska Wesleyan University IT Support: Cabling Color Codes (opens in a new tab)T568A and T568B pin 1 to 8 colours; 25-pair major and minor colour sequence and tip/ring
- Access Communications: Multi-pair telephone cable colour code (opens in a new tab)25-pair major/minor colours, tip and ring, binder groups up to 600 pairs
- Caledonian Cables: Telephone cable colour codes and make-up (opens in a new tab)25-pair tip and ring colours, binder group sequence and super-unit binders
Checked 9 Nov 2026
Binder groups in large pair-count cables
Corroborated
Binder and super-unit colours can vary by manufacturer and by cable specification.
- Access Communications: Multi-pair telephone cable colour code (opens in a new tab)25-pair major/minor colours, tip and ring, binder groups up to 600 pairs
- Caledonian Cables: Telephone cable colour codes and make-up (opens in a new tab)25-pair tip and ring colours, binder group sequence and super-unit binders
Checked 9 Nov 2026
UK telephone sockets. BT colours.
Internal UK telephone extension wiring uses the first pairs of the same code, landed on numbered IDC terminals in the master and extension sockets.
Swipe the table sideways to see every column.
| Terminal | Usual colour today | Job | Older BT colour (check) |
|---|---|---|---|
| 1 | Not used | Not connected in normal wiring | – |
| 2 | Blue with white bands | Speech and ringing (the line pair) | Blue |
| 3 | Orange with white bands | Bell (ringing) wire for older phones | Brown, green on some |
| 4 | White with orange bands | Spare, often connected for neatness | Green, brown on some |
| 5 | White with blue bands | Speech and ringing (the line pair) | Orange |
| 6 | Not used | Not connected in normal wiring | – |
Check local rules The older BT column comes from a single hobbyist source that notes local variations. Always trace both ends of the cable rather than trusting colours on old wiring.
UK BT telephone socket colours (current)
Corroborated
Always check both ends: older and DIY wiring often ignores the usual colours.
- TLC Direct: Telephone wiring (technical guide) (opens in a new tab)UK socket terminals 2, 3, 4, 5 and usual BT cable colours
- Telephones UK: Wiring info (opens in a new tab)Modern socket pin colours and older pre-1980s BT colours with conversion variations
Checked 9 Nov 2026
Older BT colours (pre-1980s)
Check local rules
Only one hobbyist source was found and it records local variations. Treat as a guide only.
- Telephones UK: Wiring info (opens in a new tab)Modern socket pin colours and older pre-1980s BT colours with conversion variations
Checked 9 Nov 2026
Fibre colours. Twelve, then repeat.
TIA-598 gives a 12-colour sequence used for both buffer tubes and the fibres inside them. Count the tube first, then the fibre within that tube.
- 1BlueBL
- 2OrangeOR
- 3GreenGR
- 4BrownBR
- 5SlateSL
- 6WhiteWH
- 7RedRD
- 8BlackBK
- 9YellowYL
- 10VioletVI
- 11RoseRS
- 12AquaAQ
Memory aid: Blue, Orange, Green, Brown, Slate, White, then Red, Black, Yellow, Violet, Rose, Aqua. The first five match the 25-pair minor colours.
Fibre number lookup
Enter a fibre count number and how many fibres each tube holds. The wheel highlights the tube (outer ring) and fibre (inner ring).
Fibre 37 is in tube 4, position 1 in that tube.
Beyond twelve.
The 13th to 24th tubes or fibres repeat the sequence with a black stripe, black dashes or a black tracer. The repeated black item needs a different mark.
| Position | As a tube | As a fibre in a 24-fibre tube |
|---|---|---|
| 13 | Blue with black stripe | Blue with black stripe or dashes |
| 14 | Orange with black stripe | Orange with black stripe or dashes |
| 15 | Green with black stripe | Green with black stripe or dashes |
| 16 | Brown with black stripe | Brown with black stripe or dashes |
| 17 | Slate with black stripe | Slate with black stripe or dashes |
| 18 | White with black stripe | White with black stripe or dashes |
| 19 | Red with black stripe | Red with black stripe or dashes |
| 20 | Black with yellow stripe | Natural (uncoloured) with black marks |
| 21 | Yellow with black stripe | Yellow with black stripe or dashes |
| 22 | Violet with black stripe | Violet with black stripe or dashes |
| 23 | Rose with black stripe | Rose with black stripe or dashes |
| 24 | Aqua with black stripe | Aqua with black stripe or dashes |
Groups beyond 24 use other stripe colours that differ between manufacturers (red and orange are both used for 25 to 36). Large tubes may also be split into bundles with coloured binder threads. Always confirm with the cable datasheet.
TIA-598 fibre and tube colour sequence
Verified
Sequence confirmed by cable manufacturers Corning and Prysmian and by the Fiber Optic Association.
- Fiber Optic Association: Fiber optic colour codes (opens in a new tab)TIA-598 12-colour sequence, striped repeats, jacket colours by fibre type and connector colours
- Corning: Optical fiber color codes (AEN 29) (opens in a new tab)12-colour sequence; fibres 13 to 24 repeat with a black tracer; fibre 20 exception
- Prysmian: Color code guide for fiber optic specifications (opens in a new tab)12-colour sequence; units 13-24 black stripe (black unit yellow stripe); 24-fibre tube marking methods
Checked 9 Nov 2026
Marking beyond 12 fibres or tubes
Corroborated
Groups 13 to 24 use a black stripe or dashes on every source. Marking for groups beyond 24, and the colour used on a repeated black item, varies between manufacturers.
- Fiber Optic Association: Fiber optic colour codes (opens in a new tab)TIA-598 12-colour sequence, striped repeats, jacket colours by fibre type and connector colours
- Corning: Optical fiber color codes (AEN 29) (opens in a new tab)12-colour sequence; fibres 13 to 24 repeat with a black tracer; fibre 20 exception
- Prysmian: Color code guide for fiber optic specifications (opens in a new tab)12-colour sequence; units 13-24 black stripe (black unit yellow stripe); 24-fibre tube marking methods
Checked 9 Nov 2026
Jacket colours. Spot the fibre type.
Indoor patch cords and premises cable are coloured by fibre type under TIA-598. Outdoor cable is usually black whatever is inside, so read the legend printed on the sheath.
- Jacket
- Orange
- Connector
- Beige
- Jacket
- Orange
- Connector
- Black
- Jacket
- Aqua
- Connector
- Aqua
- Jacket
- Aqua (violet in parts of Europe)
- Connector
- Aqua
- Jacket
- Heather or erika violet
- Connector
- Aqua or violet
- Jacket
- Lime green
- Connector
- Lime
- Jacket
- Yellow
- Connector
- Blue (UPC) or green (APC)
On-screen colours are approximate. Violet OM4 is a regional practice, mainly in the UK (heather violet) and mainland Europe (erika violet); TIA-598 itself keeps OM4 in aqua.
Jacket colours by fibre type
Corroborated
TIA-598 jacket colours for premises cable. Outdoor cable is usually black whatever the fibre.
- Fiber Optic Association: Fiber optic colour codes (opens in a new tab)TIA-598 12-colour sequence, striped repeats, jacket colours by fibre type and connector colours
- Black Box: Understanding fiber optic cable and connector colors (opens in a new tab)Jacket colours OM1 to OM5 and OS2; connector colours; violet for OM4 used by some makers but not adopted industry-wide
Checked 9 Nov 2026
Violet OM4 jackets
Corroborated
A regional and manufacturer practice, mainly in Europe. Aqua is still the TIA-598 colour for OM4.
- Belden: Differentiating between OM3 and OM4 (opens in a new tab)OM4 traditionally aqua; violet OM4 (heather violet in the UK, erika violet in mainland Europe)
- Black Box: Understanding fiber optic cable and connector colors (opens in a new tab)Jacket colours OM1 to OM5 and OS2; connector colours; violet for OM4 used by some makers but not adopted industry-wide
Checked 9 Nov 2026
Connector colours. Blue, green, beige, aqua.
Connector bodies, boots and through-adapters follow the fibre type, and for singlemode they also show the polish. Mixing them causes loss and can damage end faces.
Never mate green with blue. An APC connector is polished at 8° so reflections are sent out of the core. Pushing it into a UPC connector leaves an air gap at an angle, causing high loss and possible end-face damage. If an adapter is green, both connectors should be green.
Connector colours
Corroborated
Colours apply to connector bodies, boots and adapters. Never rely on colour alone to tell APC from UPC: check the endface.
- Fiber Optic Association: Fiber optic colour codes (opens in a new tab)TIA-598 12-colour sequence, striped repeats, jacket colours by fibre type and connector colours
- Black Box: Understanding fiber optic cable and connector colors (opens in a new tab)Jacket colours OM1 to OM5 and OS2; connector colours; violet for OM4 used by some makers but not adopted industry-wide
- Fluke Networks: What is an APC connector and how do I test it? (opens in a new tab)Blue bodies are UPC, green are APC with an 8 degree endface; UPC and APC cannot be mated
Checked 9 Nov 2026
Work safely. Light, glass and power.
Data cabling is low voltage, but it is rarely the only thing in the ceiling void. These are the hazards that catch people out.
1Never look into a fibre
Network lasers work in the infrared, so a live fibre looks dark. Do not look into a fibre end or a connector, and never through a microscope, until a power meter or live-fibre detector has shown it is dark. Point visual fault locators away from your face.
2Treat offcuts as glass
Cleaved fibre ends are tiny, sharp and almost invisible. Wear safety glasses, put every offcut in a marked sealed container, keep food and drink away from the work area and wash your hands before touching your eyes.
3PoE puts power on the cable
PoE cables are live while the switch port is on. High-power PoE warms cable bundles, so follow the cable maker’s advice on bundle size and avoid large, tightly combed bundles. Use connectors rated for unplugging while powered.
4Keep data apart from mains
Under BS 7671, data (Band I) and mains (Band II) circuits may only share containment if every cable is insulated for the highest voltage present, or they run in separate compartments or separate containment. BS EN 50174-2 adds separation distances that depend on how the cables are screened and contained. Where data and power cables must cross, protect the crossing, and never share a compartment with exposed live terminals.
Fibre laser and glass safety
Corroborated
Safety guidance from the Fiber Optic Association and Fluke Networks.
- Fiber Optic Association: Fiber optic safety (opens in a new tab)Infrared light is invisible; check with a power meter; fibre shard handling; chemicals
- Fluke Networks: 5 vital safety rules for working with fiber optic cables (opens in a new tab)Never look into the end of a fibre; contain glass fragments; work near power
Checked 9 Nov 2026
Separating data cables from power
Corroborated
Principles only. Take distances from BS EN 50174-2, BS 7671 and the cable maker.
- Voltimum / NICEIC: Installation of Band I and Band II circuits (opens in a new tab)BS 7671 Regulation 528.1 segregation methods and 528.2 proximity to other services
- Professional Electrician: Networking data cables, the key requirements (opens in a new tab)BS 7671 528.1 shared wiring systems; support of data cables in fire
- Mayflex: What are separation distances? (opens in a new tab)EN 50174-2 separation between telecoms and LV power cabling depends on what separates them
Checked 9 Nov 2026
Run the numbers. Then learn the trade.
Check PoE power budgets, voltage drop and cable sizing with the Tradefox electrical calculators.