Tradefox

Tradefox – Build Skills

Learn Construction

‹ All bricklaying calculators

Setting out

Fit units between two ends

j=S−nlnj
where
j
perpend joint width (mm)
S
span (mm)
n
unit count
l
unit length (mm)
nj
number of joints included
Explain this equation

This finds the uniform perpend joint needed to fit a known number of units into a fixed span, such as between two piers.

S is the span in mm. n is the number of units and l is the length of one unit, so n × l is the length taken up by the units. n_j is the number of perpend joints you are including in the span. j is the joint width each one must be.

The space the units do not fill must be taken up by the joints, so S − nl is shared equally between them. Between two free ends there is usually one joint fewer than units; building up to existing work may add end joints.

Four 215 mm bricks in an 890 mm span take 860 mm, leaving 30 mm for three joints: 10 mm each.

Watch out: a very thin or very wide answer means the layout needs changing, not forcing. The calculator stops if the units alone fill the span.

Find a uniform perpend joint from a known span, unit count and joint count.

mm
mm

Enter your values to see the result.

Estimates are not design approval or British Standards compliance checks. Structural arch, retaining-wall, wind, foundation, lintel and masonry-capacity design are not performed. Use the project engineer’s specification.