Setting out
Courses within a target height
- where
- whole courses
- target height (mm)
- gauge = unit height + bed joint (mm)
- remainder (mm)
Explain this equation
This tells you how many whole courses fit within a target height and how much is left over. Use it when working to a fixed height such as a sill, a lintel or a floor level.
H is the target height in mm. g is the gauge, which is the unit height plus one bed joint. n is the number of whole courses that fit, and r is the leftover height that is less than one course. The calculator also shows the height of n + 1 courses, the next full course above the target.
Dividing the target by the gauge gives the number of courses, and the ⌊ ⌋ brackets mean round down, because only complete courses fit. Whatever height those whole courses do not use is the remainder, H − n × g.
With a 75 mm gauge, 2450 mm holds 32 courses (2400 mm) with 50 mm left over; 33 courses would reach 2475 mm.
Watch out: do not simply spread the remainder across the joints. Check the permitted joint tolerances and the design first.
Find whole course modules and the residual height.
Enter your values to see the result.
Good to know
Do not spread the remainder into joints without checking permitted joint tolerances and the design. Includes one bed per course.
Sources
Estimates are not design approval or British Standards compliance checks. Structural arch, retaining-wall, wind, foundation, lintel and masonry-capacity design are not performed. Use the project engineer’s specification.
Worked example
The drawing puts a window sill 1120 mm above DPC, built in 65 mm bricks with 10 mm beds (75 mm gauge). n = ⌊1120 ÷ 75⌋ = 14 courses, which reach 1050 mm, leaving r = 1120 − 1050 = 70 mm, while 15 courses would reach 1125 mm. Fifteen courses lands just 5 mm above the drawing height, so it is worth asking whether the sill can sit at 1125 mm rather than cutting a 70 mm course.
Common questions
What do I do with a remainder that is nearly a full course?
If it is within a few millimetres of a full course, it is often simplest to agree a small change in the target height and lay the extra course. Check with the designer if the height is tied to a floor level, window or roof line.
Can I make up the remainder with a thicker bed joint?
Only within the joint tolerances allowed by the specification, and spread over several courses rather than one. A 70 mm gap is too much to lose in the joints and needs a cut course, a different unit or a change of height.
Should I count the first bed on the DPC?
Yes, this calculator includes one bed joint under every course, including the first one on the DPC or footing. If your datum is the top of a bed already laid, take one bed off.