{"id":18052,"date":"2026-05-28T08:05:53","date_gmt":"2026-05-28T08:05:53","guid":{"rendered":"https:\/\/tradefoxapp.com\/?p=18052"},"modified":"2026-05-28T08:07:52","modified_gmt":"2026-05-28T08:07:52","slug":"first-fix-second-fix","status":"publish","type":"post","link":"https:\/\/tradefoxapp.com\/fr\/first-fix-second-fix\/","title":{"rendered":"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"18052\" class=\"elementor elementor-18052\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd69d62 e-flex e-con-boxed e-con e-parent\" data-id=\"bd69d62\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cfb4151 elementor-widget elementor-widget-text-editor\" data-id=\"cfb4151\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">For electrical contractors managing new builds, extensions, or major renovations, construction phasing dictates the workflow of the entire site. The division of labour generally falls into two highly distinct categories. Understanding the detailed nuances of First Fix vs Second Fix Electrical is essential for maintaining site efficiency, adhering to the project schedule, and ensuring strict compliance with UK electrical regulations.<\/span><\/p><p><span style=\"font-weight: 400;\">This guide breaks down exactly what happens during each phase, the updated regulatory requirements involved, and the safety protocols that professional electricians must follow. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1648910 e-flex e-con-boxed e-con e-parent\" data-id=\"1648910\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f6d514b elementor-widget elementor-widget-heading\" data-id=\"f6d514b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The Fundamentals of Electrical Phasing\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fdbd47d elementor-widget elementor-widget-text-editor\" data-id=\"fdbd47d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Before plasterboards go up or finished floors are laid, the internal infrastructure of a building must be installed. The electrical installation process is split into two halves to accommodate other trades, such as plasterers, plumbers, and carpenters.<\/span><\/p><p><span style=\"font-weight: 400;\">The primary difference between the two stages comes down to access, structural alteration, and termination. The first stage involves all the hidden wiring and structural preparations. The second stage involves connecting the visible accessories and commissioning the system. A masterly execution of First Fix vs Second Fix Electrical ensures that the final installation is safe, compliant, and visually flawless, completely eliminating the need for destructive remedial work later down the line.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-68fb85a e-flex e-con-boxed e-con e-parent\" data-id=\"68fb85a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7522c86 elementor-widget elementor-widget-heading\" data-id=\"7522c86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">First Fix Electrical: Laying the Groundwork\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1dba35 elementor-widget elementor-widget-text-editor\" data-id=\"d1dba35\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">The initial phase occurs when the building is at the shell stage. The structural framework is visible, stud walls are open, and floor joists are fully exposed. The objective here is to install the backbone of the electrical system without making any live connections. \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-332693b elementor-widget elementor-widget-heading\" data-id=\"332693b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Preparation and Marking Out\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d269f3d elementor-widget elementor-widget-text-editor\" data-id=\"d269f3d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Electricians work directly from the architect or lighting designer drawings to mark the exact locations for sockets, switches, lighting points, and the consumer unit. For solid masonry walls, contractors use a wall chaser and an SDS drill with a chasing bit to create precise channels for cables and deep recesses for metal back boxes.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-408d86b elementor-widget elementor-widget-heading\" data-id=\"408d86b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Routing Cables Through Joists and Studs\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1b15f4 elementor-widget elementor-widget-text-editor\" data-id=\"d1b15f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Routing cables is one of the most labour-intensive parts of the job. Cables, typically Twin and Earth for domestic circuits, are pulled from the consumer unit location to the respective back boxes and ceiling roses.<\/span><\/p><p><span style=\"font-weight: 400;\">When routing cables through timber joists, electricians must strictly adhere to Building Regulations Approved Document A. Holes must be drilled exclusively on the neutral axis of the timber. Furthermore, these holes must only be located within the permitted zone of 0.25 to 0.4 times the span of the joist from the support. This regulation guarantees the structural integrity of the floor is never compromised by the electrical installation.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6de4336 elementor-widget elementor-widget-heading\" data-id=\"6de4336\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Safe Zones and Wall Chases\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5f1a66 elementor-widget elementor-widget-text-editor\" data-id=\"c5f1a66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Safety and compliance during the initial wiring are highly regulated. According to the 18th Edition of the IET Wiring Regulations (BS 7671), all concealed cables must be installed in designated safe zones. These zones run vertically and horizontally from any visible electrical accessory, as well as within 150mm of the top of the wall or the internal corner of a room.<\/span><\/p><p><span style=\"font-weight: 400;\">If a cable is buried in a wall at a depth of less than 50mm and is not mechanically protected by earthed metallic conduit, it must be protected by a 30mA Residual Current Device (RCD). Cables chased into walls are usually secured with plastic capping or oval PVC conduit. While capping does not provide mechanical protection against a drilled screw, it successfully protects the cable insulation from the trowel during the wet plastering process.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55eb47b e-flex e-con-boxed e-con e-parent\" data-id=\"55eb47b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-98c8b48 elementor-widget elementor-widget-heading\" data-id=\"98c8b48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The Transition: Managing the Plastering Phase\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d15c556 elementor-widget elementor-widget-text-editor\" data-id=\"d15c556\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Once the cables are run and the back boxes are secured, the electrical contractor leaves the site. This allows the plasterer to board the ceilings and skim the walls. Electricians leave the cables safely coiled within the back boxes or dangling clearly from ceiling points.<\/span><\/p><p><span style=\"font-weight: 400;\">Communication between trades is highly important during this transition. Plasterers burying back boxes or cutting cables too short is a frequent issue on busy sites. Professional electricians take detailed photographs of their cable runs before the boarding begins. This provides a reliable reference point if cables need to be located later using a stud detector or if an accessory is accidentally plastered over.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d7c3a1a e-flex e-con-boxed e-con e-parent\" data-id=\"d7c3a1a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7caf894 elementor-widget elementor-widget-heading\" data-id=\"7caf894\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Second Fix Electrical: Termination and Commissioning\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e0385c elementor-widget elementor-widget-image\" data-id=\"6e0385c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"825\" height=\"550\" src=\"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Termination-and-Commissioning.png\" class=\"attachment-large size-large wp-image-18053\" alt=\"Termination and Commissioning\" srcset=\"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Termination-and-Commissioning.png 825w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Termination-and-Commissioning-300x200.png 300w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Termination-and-Commissioning-768x512.png 768w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Termination-and-Commissioning-18x12.png 18w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Termination-and-Commissioning-600x400.png 600w\" sizes=\"(max-width: 825px) 100vw, 825px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2912670 elementor-widget elementor-widget-text-editor\" data-id=\"2912670\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">The latter phase commences once the plaster is entirely dry, the building is watertight, and the heavy dust levels have subsided. The structural work is finished, and the objective now is to terminate all connections, fit the final accessories, and energise the system.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9ae93a2 elementor-widget elementor-widget-heading\" data-id=\"9ae93a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Safe Isolation Procedures\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9411cc4 elementor-widget elementor-widget-text-editor\" data-id=\"9411cc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Before any termination begins, particularly at the consumer unit, strict Safe Isolation procedures must be followed. Electricians must lock off the supply if a temporary site supply is active. They must then verify the circuit is completely dead using an approved voltage indicator and a proving unit. Working dead is the golden rule of electrical safety and is legally required under the Electricity at Work Regulations 1989.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3735cf8 elementor-widget elementor-widget-heading\" data-id=\"3735cf8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Accessory Installation\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6dea658 elementor-widget elementor-widget-text-editor\" data-id=\"6dea658\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Electricians begin the physical work by cleaning out the back boxes, removing any stray plaster, and ensuring all cables are free from damage. Protective green and yellow sleeving is applied to all bare earth wires.<\/span><\/p><p><span style=\"font-weight: 400;\">Faceplates for sockets, light switches, dimmer modules, and data points are then wired and screwed into place. Installers take great care to ensure all faceplates are perfectly level and securely tightened to the wall surface. For ceiling lights, the electrician will carefully cut holes in the plasterboard using a hole saw, retrieve the initial wiring, and connect the light engines.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fbdd30a elementor-widget elementor-widget-heading\" data-id=\"fbdd30a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Consumer Unit Terminations\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d303de elementor-widget elementor-widget-text-editor\" data-id=\"8d303de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Terminating the distribution board is a highly critical task requiring absolute precision. The electrician strips the outer sheathing of the main incoming tails and all circuit cables. These are terminated into the appropriate breakers, such as MCBs or RCBOs.<\/span><\/p><p><span style=\"font-weight: 400;\">Modern installations must also comply with recent updates. Installers now regularly integrate Surge Protection Devices (SPDs) and Arc Fault Detection Devices (AFDDs) where required by BS 7671 Amendment 2. All connections within the consumer unit must be tightened to the specific torque settings provided by the manufacturer. Regulation 134.1.1 mandates this practice to prevent loose connections, arcing, and subsequent thermal damage.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-146af9c e-flex e-con-boxed e-con e-parent\" data-id=\"146af9c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4cdfa7d elementor-widget elementor-widget-heading\" data-id=\"4cdfa7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Inspection, Testing, and Certification\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c50a923 elementor-widget elementor-widget-image\" data-id=\"c50a923\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"825\" height=\"550\" src=\"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Inspection-Testing-and-Certification.png\" class=\"attachment-large size-large wp-image-18055\" alt=\"Inspection, Testing, and Certification\" srcset=\"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Inspection-Testing-and-Certification.png 825w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Inspection-Testing-and-Certification-300x200.png 300w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Inspection-Testing-and-Certification-768x512.png 768w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Inspection-Testing-and-Certification-18x12.png 18w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/Inspection-Testing-and-Certification-600x400.png 600w\" sizes=\"(max-width: 825px) 100vw, 825px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-523c740 elementor-widget elementor-widget-text-editor\" data-id=\"523c740\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">The most vital element of the entire project is the final testing phase. Before the installation is handed over to the client, it must be rigorously tested to prove it complies with all safety standards.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e94db80 elementor-widget elementor-widget-heading\" data-id=\"e94db80\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Part P and Final Certification\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-037ec72 elementor-widget elementor-widget-text-editor\" data-id=\"037ec72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Domestic electrical work falls under Part P of the Building Regulations. This legislation requires notification to local building control for major works like new circuits or consumer unit replacements. This notification is usually completed via a competent person scheme. Upon successful completion of all physical tests, the electrician generates an Electrical Installation Certificate. This legal document verifies that the design, construction, inspection, and testing meet current UK safety standards. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2cb3af0 e-flex e-con-boxed e-con e-parent\" data-id=\"2cb3af0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3baa387 elementor-widget elementor-widget-heading\" data-id=\"3baa387\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comparing the Two Phases\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f2a040 elementor-widget elementor-widget-text-editor\" data-id=\"0f2a040\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">To consolidate the comparison of First Fix vs Second Fix Electrical, the practical distinction is very clear. The early stage is entirely about infrastructure, structural preparation, and strategic cable management. It requires heavy power tools, creates significant dust, and focuses heavily on correct routing and safe zones.<\/span><\/p><p><span style=\"font-weight: 400;\">The later stage is about precision, termination, testing, and aesthetics. It requires a clean working environment, fine hand tools, and a deep, practiced understanding of electrical testing procedures.\u00a0<\/span><\/p><p><span style=\"font-weight: 400;\">For anyone learning the trade, this difference is important to understand early. <\/span><strong><a href=\"https:\/\/learn.tradefoxapp.com\/\">TradeFox<\/a><\/strong><span style=\"font-weight: 400;\"> helps learners build confidence in electrical work through guided, step-by-step training that makes it easier to grasp both the practical groundwork of first fix and the careful finishing standards required during second fix. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c846983 e-flex e-con-boxed e-con e-parent\" data-id=\"c846983\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-00e1388 elementor-widget elementor-widget-heading\" data-id=\"00e1388\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion \n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7575cd8 elementor-widget elementor-widget-text-editor\" data-id=\"7575cd8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Mastering the complete workflow of First Fix vs Second Fix Electrical is fundamental to any successful construction or renovation project. By understanding the distinct roles, updated regulations, and stringent safety protocols required at each stage, electrical contractors ensure a seamless and highly professional installation process. Adherence to BS 7671, meticulous structural drilling, and comprehensive final testing are absolute legal requirements designed to protect both lives and property.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>For electrical contractors managing new builds, extensions, or major renovations, construction phasing dictates the workflow of the entire site. The division of labour generally falls into two highly distinct categories. Understanding the detailed nuances of First Fix vs Second Fix Electrical is essential for maintaining site efficiency, adhering to the project schedule, and ensuring strict [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":18054,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_glsr_average":0,"_glsr_ranking":0,"_glsr_reviews":0,"footnotes":""},"categories":[1],"tags":[277,741,640,582,834,832,833,835,143,831,647],"class_list":["post-18052","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical","tag-consumer-unit","tag-depending-on-the-size","tag-electrical-cables","tag-electrical-installation","tag-fix-and-second-fix","tag-fix-electrical","tag-fix-work","tag-fuse-boards","tag-light-fittings","tag-socket-switch","tag-walls-and-ceilings"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project<\/title>\n<meta name=\"description\" content=\"First Fix vs Second Fix Electrical explained clearly, from hidden wiring and safe zones to final fittings, testing, and certification.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tradefoxapp.com\/fr\/first-fix-second-fix\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project\" \/>\n<meta property=\"og:description\" content=\"First Fix vs Second Fix Electrical explained clearly, from hidden wiring and safe zones to final fittings, testing, and certification.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tradefoxapp.com\/fr\/first-fix-second-fix\/\" \/>\n<meta property=\"og:site_name\" content=\"Tradefox | Construction Training Online\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61561067514381\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-28T08:05:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-28T08:07:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/What-Happens-at-Each-Stage-of-a-Project.png\" \/>\n\t<meta property=\"og:image:width\" content=\"825\" \/>\n\t<meta property=\"og:image:height\" content=\"550\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tradefoxapp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tradefox_app\" \/>\n<meta name=\"twitter:site\" content=\"@Tradefox_app\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tradefoxapp\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/\"},\"author\":{\"name\":\"Tradefoxapp\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#\\\/schema\\\/person\\\/cad3ebca9b0c18ad17cdf9222b9e4d06\"},\"headline\":\"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project\",\"datePublished\":\"2026-05-28T08:05:53+00:00\",\"dateModified\":\"2026-05-28T08:07:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/\"},\"wordCount\":1299,\"publisher\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/What-Happens-at-Each-Stage-of-a-Project.png\",\"keywords\":[\"consumer unit\",\"depending on the size\",\"electrical cables\",\"electrical installation\",\"fix and second fix\",\"fix electrical\",\"fix work\",\"fuse boards\",\"light fittings\",\"socket switch\",\"walls and ceilings\"],\"articleSection\":[\"Electrical\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/\",\"name\":\"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/What-Happens-at-Each-Stage-of-a-Project.png\",\"datePublished\":\"2026-05-28T08:05:53+00:00\",\"dateModified\":\"2026-05-28T08:07:52+00:00\",\"description\":\"First Fix vs Second Fix Electrical explained clearly, from hidden wiring and safe zones to final fittings, testing, and certification.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/What-Happens-at-Each-Stage-of-a-Project.png\",\"contentUrl\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/What-Happens-at-Each-Stage-of-a-Project.png\",\"width\":825,\"height\":550,\"caption\":\"What Happens at Each Stage of a Project\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/first-fix-second-fix\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/tradefoxapp.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#website\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/\",\"name\":\"Tradefox | Construction Training Online\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tradefoxapp.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#organization\",\"name\":\"Tradefox | Construction Training Online\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/logo-transperent.png\",\"contentUrl\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/logo-transperent.png\",\"width\":1024,\"height\":208,\"caption\":\"Tradefox | Construction Training Online\"},\"image\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=61561067514381\",\"https:\\\/\\\/x.com\\\/Tradefox_app\",\"https:\\\/\\\/www.instagram.com\\\/tradefoxapp\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/tradefox-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#\\\/schema\\\/person\\\/cad3ebca9b0c18ad17cdf9222b9e4d06\",\"name\":\"Tradefoxapp\",\"sameAs\":[\"https:\\\/\\\/tradefoxapp.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project","description":"First Fix vs Second Fix Electrical explained clearly, from hidden wiring and safe zones to final fittings, testing, and certification.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tradefoxapp.com\/fr\/first-fix-second-fix\/","og_locale":"fr_FR","og_type":"article","og_title":"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project","og_description":"First Fix vs Second Fix Electrical explained clearly, from hidden wiring and safe zones to final fittings, testing, and certification.","og_url":"https:\/\/tradefoxapp.com\/fr\/first-fix-second-fix\/","og_site_name":"Tradefox | Construction Training Online","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61561067514381","article_published_time":"2026-05-28T08:05:53+00:00","article_modified_time":"2026-05-28T08:07:52+00:00","og_image":[{"width":825,"height":550,"url":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/What-Happens-at-Each-Stage-of-a-Project.png","type":"image\/png"}],"author":"Tradefoxapp","twitter_card":"summary_large_image","twitter_creator":"@Tradefox_app","twitter_site":"@Tradefox_app","twitter_misc":{"\u00c9crit par":"Tradefoxapp","Dur\u00e9e de lecture estim\u00e9e":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/#article","isPartOf":{"@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/"},"author":{"name":"Tradefoxapp","@id":"https:\/\/tradefoxapp.com\/#\/schema\/person\/cad3ebca9b0c18ad17cdf9222b9e4d06"},"headline":"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project","datePublished":"2026-05-28T08:05:53+00:00","dateModified":"2026-05-28T08:07:52+00:00","mainEntityOfPage":{"@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/"},"wordCount":1299,"publisher":{"@id":"https:\/\/tradefoxapp.com\/#organization"},"image":{"@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/#primaryimage"},"thumbnailUrl":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/What-Happens-at-Each-Stage-of-a-Project.png","keywords":["consumer unit","depending on the size","electrical cables","electrical installation","fix and second fix","fix electrical","fix work","fuse boards","light fittings","socket switch","walls and ceilings"],"articleSection":["Electrical"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/","url":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/","name":"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project","isPartOf":{"@id":"https:\/\/tradefoxapp.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/#primaryimage"},"image":{"@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/#primaryimage"},"thumbnailUrl":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/What-Happens-at-Each-Stage-of-a-Project.png","datePublished":"2026-05-28T08:05:53+00:00","dateModified":"2026-05-28T08:07:52+00:00","description":"First Fix vs Second Fix Electrical explained clearly, from hidden wiring and safe zones to final fittings, testing, and certification.","breadcrumb":{"@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tradefoxapp.com\/first-fix-second-fix\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/#primaryimage","url":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/What-Happens-at-Each-Stage-of-a-Project.png","contentUrl":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/05\/What-Happens-at-Each-Stage-of-a-Project.png","width":825,"height":550,"caption":"What Happens at Each Stage of a Project"},{"@type":"BreadcrumbList","@id":"https:\/\/tradefoxapp.com\/first-fix-second-fix\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/tradefoxapp.com\/"},{"@type":"ListItem","position":2,"name":"First Fix vs Second Fix Electrical: What Happens at Each Stage of a Project"}]},{"@type":"WebSite","@id":"https:\/\/tradefoxapp.com\/#website","url":"https:\/\/tradefoxapp.com\/","name":"Tradefox | Formation en construction en ligne","description":"","publisher":{"@id":"https:\/\/tradefoxapp.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tradefoxapp.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/tradefoxapp.com\/#organization","name":"Tradefox | Formation en construction en ligne","url":"https:\/\/tradefoxapp.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tradefoxapp.com\/#\/schema\/logo\/image\/","url":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/03\/logo-transperent.png","contentUrl":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/03\/logo-transperent.png","width":1024,"height":208,"caption":"Tradefox | Construction Training Online"},"image":{"@id":"https:\/\/tradefoxapp.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=61561067514381","https:\/\/x.com\/Tradefox_app","https:\/\/www.instagram.com\/tradefoxapp\/","https:\/\/www.linkedin.com\/company\/tradefox-ltd\/"]},{"@type":"Person","@id":"https:\/\/tradefoxapp.com\/#\/schema\/person\/cad3ebca9b0c18ad17cdf9222b9e4d06","name":"Tradefoxapp","sameAs":["https:\/\/tradefoxapp.com"]}]}},"_links":{"self":[{"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/posts\/18052","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/comments?post=18052"}],"version-history":[{"count":10,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/posts\/18052\/revisions"}],"predecessor-version":[{"id":18065,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/posts\/18052\/revisions\/18065"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/media\/18054"}],"wp:attachment":[{"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/media?parent=18052"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/categories?post=18052"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/tags?post=18052"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}