{"id":10166,"date":"2025-10-23T04:57:20","date_gmt":"2025-10-23T04:57:20","guid":{"rendered":"https:\/\/tradefoxapp.com\/?p=10166"},"modified":"2025-12-16T05:21:35","modified_gmt":"2025-12-16T05:21:35","slug":"continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes","status":"publish","type":"post","link":"https:\/\/tradefoxapp.com\/fr\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/","title":{"rendered":"Test de continuit\u00e9 sur les circuits : Pas \u00e0 pas avec les sondes conformes \u00e0 la norme GS38"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"10166\" class=\"elementor elementor-10166\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c601f30 e-flex e-con-boxed e-con e-parent\" data-id=\"c601f30\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9724773 elementor-widget elementor-widget-text-editor\" data-id=\"9724773\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Lors du test d'un circuit \u00e9lectrique, la continuit\u00e9 est l'un des contr\u00f4les de s\u00e9curit\u00e9 les plus fondamentaux. Elle permet de s'assurer que chaque conducteur, chaque connexion et chaque chemin de protection sont intacts avant que le syst\u00e8me ne soit sous tension. Mais pour effectuer ce test correctement, il ne suffit pas de brancher un appareil de mesure et d'attendre un signal sonore.\u00a0<\/span><\/p><p><span style=\"font-weight: 400;\">Il s'agit de respecter la norme BS 7671 et, tout aussi important, de s'assurer que votre \u00e9quipement de test et vos sondes sont conformes \u00e0 la norme GS38 pour des raisons de s\u00e9curit\u00e9.<\/span><\/p><p><span style=\"font-weight: 400;\">Ce guide vous guide pas \u00e0 pas dans les tests de continuit\u00e9, en expliquant les normes, la s\u00e9lection de sondes s\u00fbres et les m\u00e9thodes de test professionnelles utilis\u00e9es sur les sites domestiques et commerciaux du Royaume-Uni.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2e1ddc elementor-widget elementor-widget-heading\" data-id=\"b2e1ddc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ce que les tests de continuit\u00e9 prouvent : et pourquoi c'est important ?\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a10bf7 elementor-widget elementor-widget-text-editor\" data-id=\"9a10bf7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Le test de continuit\u00e9 prouve que les conducteurs d'un circuit (ligne, neutre, CPC ou liaison) forment un chemin complet et ininterrompu. Sans cela, les dispositifs de protection tels que les disjoncteurs diff\u00e9rentiels et les disjoncteurs de puissance ne peuvent pas fonctionner comme pr\u00e9vu en cas de d\u00e9faillance.<\/span><\/p><p><span style=\"font-weight: 400;\">Le test v\u00e9rifie :<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-963da53 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"963da53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tous les conducteurs de protection sont reli\u00e9s \u00e0 la terre.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Les conducteurs de liaison sont reli\u00e9s entre les syst\u00e8mes m\u00e9talliques (gaz, eau, structure).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Les interrupteurs, les fusibles et les joints ont une continuit\u00e9 \u00e0 faible r\u00e9sistance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2d57292 elementor-widget elementor-widget-text-editor\" data-id=\"2d57292\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">En termes pratiques, le test de continuit\u00e9 est la preuve de l'int\u00e9grit\u00e9 m\u00e9canique et \u00e9lectrique avant la mise sous tension.\u00a0<\/span><\/p><p><span style=\"font-weight: 400;\">Un seul joint ouvert ou une seule connexion \u00e0 haute r\u00e9sistance peut compromettre la s\u00e9curit\u00e9 ou provoquer des d\u00e9clenchements intempestifs lorsque le circuit est sous tension.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4604b3c elementor-widget elementor-widget-heading\" data-id=\"4604b3c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Le GS38 expliqu\u00e9 : Pourquoi n'est-elle pas facultative ?\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cebc612 elementor-widget elementor-widget-text-editor\" data-id=\"cebc612\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><b>GS38<\/b><span style=\"font-weight: 400;\"> se r\u00e9f\u00e8re \u00e0 la <\/span><i><span style=\"font-weight: 400;\">Note d'orientation GS38 de l'ex\u00e9cutif charg\u00e9 de la sant\u00e9 et de la s\u00e9curit\u00e9,<\/span><\/i><span style=\"font-weight: 400;\"> qui couvre les exigences minimales de s\u00e9curit\u00e9 pour les cordons de mesure et les sondes utilis\u00e9s sur les syst\u00e8mes \u00e9lectriques.<\/span><\/p><p><span style=\"font-weight: 400;\">En bref, la conformit\u00e9 \u00e0 la norme GS38 signifie<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7f5eb0 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b7f5eb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Les pointes des sondes sont partiellement recouvertes, avec un maximum de 4 mm de m\u00e9tal expos\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Les fils sont enti\u00e8rement isol\u00e9s, \u00e0 double couche et marqu\u00e9s d'une tension nominale (g\u00e9n\u00e9ralement 1000V CAT III).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Les c\u00e2bles \u00e0 fusible sont utilis\u00e9s lorsque des circuits sous tension sont test\u00e9s afin de limiter l'\u00e9nergie de d\u00e9faut.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7e1f34 elementor-widget elementor-widget-text-editor\" data-id=\"f7e1f34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Les tests de continuit\u00e9 sont effectu\u00e9s sur des circuits isol\u00e9s (morts), mais la norme GS38 s'applique toujours. Des accidents se produisent lorsque l'isolation n'est pas v\u00e9rifi\u00e9e correctement ou que les outils se d\u00e9gradent avec le temps. L'utilisation de sondes conformes n'est pas exag\u00e9r\u00e9e, c'est la norme professionnelle minimale.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f0d867 elementor-widget elementor-widget-heading\" data-id=\"2f0d867\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Outils essentiels et pr\u00e9paration\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3d6f6c elementor-widget elementor-widget-text-editor\" data-id=\"f3d6f6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Avant de commencer les tests, la pr\u00e9paration est essentielle \u00e0 la pr\u00e9cision et \u00e0 la s\u00e9curit\u00e9. Munissez-vous de vos outils et assurez-vous qu'ils sont en bon \u00e9tat de marche.<\/span><\/p><p><span style=\"font-weight: 400;\">Vous aurez besoin de.. :<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f8fb4af elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"f8fb4af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Un testeur d'installation multifonction (MFT) ou un ohmm\u00e8tre \u00e0 faible r\u00e9sistance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sondes et fils conformes \u00e0 la norme GS38 (v\u00e9rifier la longueur de la gaine et l'isolation).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Kit de consignation\/\u00e9tiquetage pour isoler les circuits.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Certificat d'\u00e9talonnage (votre instrument de test doit \u00eatre \u00e0 jour).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e521b9a elementor-widget elementor-widget-text-editor\" data-id=\"e521b9a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">V\u00e9rifiez ensuite :<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9846e9c elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"9846e9c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">L'alimentation est isol\u00e9e en toute s\u00e9curit\u00e9 au niveau de l'unit\u00e9 de consommation ou du tableau de distribution.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le circuit est mort, \u00e0 l'aide d'un appareil de contr\u00f4le et d'un testeur de tension.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Les conducteurs sont identifi\u00e9s et \u00e9tiquet\u00e9s, en particulier lorsque plusieurs circuits partagent l'enceinte de confinement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f31792 elementor-widget elementor-widget-text-editor\" data-id=\"2f31792\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">La pr\u00e9paration permet d'\u00e9viter les fausses lectures et les travaux ult\u00e9rieurs, en particulier dans les cas de rec\u00e2blage ou de syst\u00e8mes multiphases.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cfd4432 e-flex e-con-boxed e-con e-parent\" data-id=\"cfd4432\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea707e1 elementor-widget elementor-widget-heading\" data-id=\"ea707e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pas \u00e0 pas : Test de continuit\u00e9 des CPC\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4095cf elementor-widget elementor-widget-image\" data-id=\"c4095cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"825\" height=\"550\" src=\"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-man-overalls-works-switchboard-portrait-electrician-overalls.jpg\" class=\"attachment-large size-large wp-image-10178\" alt=\"\" srcset=\"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-man-overalls-works-switchboard-portrait-electrician-overalls.jpg 825w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-man-overalls-works-switchboard-portrait-electrician-overalls-300x200.jpg 300w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-man-overalls-works-switchboard-portrait-electrician-overalls-768x512.jpg 768w, https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-man-overalls-works-switchboard-portrait-electrician-overalls-600x400.jpg 600w\" sizes=\"(max-width: 825px) 100vw, 825px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-136d1be elementor-widget elementor-widget-text-editor\" data-id=\"136d1be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Le contr\u00f4le de continuit\u00e9 le plus courant concerne le CPC. L'objectif est de s'assurer que chaque prise, raccord ou accessoire dispose d'une mise \u00e0 la terre continue jusqu'\u00e0 la borne principale de mise \u00e0 la terre (MET).<\/span><\/p><p><span style=\"font-weight: 400;\">Voici la m\u00e9thode professionnelle :<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24e4175 elementor-widget elementor-widget-heading\" data-id=\"24e4175\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">1. Tester d'abord les principaux liens de protection\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60797b4 elementor-widget elementor-widget-text-editor\" data-id=\"60797b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Avant de tester les CPC individuels, il convient de tester les principaux conducteurs de liaison de protection avec les services (eau, gaz, charpente m\u00e9tallique). Cela permet de s'assurer que l'ensemble du syst\u00e8me de mise \u00e0 la terre est en bon \u00e9tat.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe5b081 elementor-widget elementor-widget-heading\" data-id=\"fe5b081\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">2. Ligne de liaison et CPC au conseil d'administration\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f77a221 elementor-widget elementor-widget-text-editor\" data-id=\"f77a221\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Le circuit \u00e9tant isol\u00e9, relier le conducteur de ligne (L) au CPC \u00e0 l'origine du circuit. Cela cr\u00e9e un chemin de boucle pour la mesure \u00e0 partir de n'importe quel point accessoire.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a57ddd5 elementor-widget elementor-widget-heading\" data-id=\"a57ddd5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">3. Mesurer la r\u00e9sistance au point le plus \u00e9loign\u00e9\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-431ccae elementor-widget elementor-widget-text-editor\" data-id=\"431ccae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Allez \u00e0 la prise ou au point lumineux le plus \u00e9loign\u00e9 et mesurez la distance entre la ligne et les bornes du CPC.<\/span><span style=\"font-weight: 400;\"><br \/><\/span><span style=\"font-weight: 400;\">Une valeur faible (g\u00e9n\u00e9ralement inf\u00e9rieure \u00e0 1 ohm) signifie qu'il y a continuit\u00e9.<\/span><\/p><p><span style=\"font-weight: 400;\">Si les relev\u00e9s sont diff\u00e9rents en diff\u00e9rents points, rev\u00e9rifiez les joints ou les connexions, une borne ou une bo\u00eete de jonction mal fix\u00e9e peut introduire une r\u00e9sistance.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea5f4e2 elementor-widget elementor-widget-heading\" data-id=\"ea5f4e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">4. Comparer et enregistrer\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e75846e elementor-widget elementor-widget-text-editor\" data-id=\"e75846e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Comparez les relev\u00e9s aux valeurs attendues en utilisant les longueurs des conducteurs et les surfaces de section (d'apr\u00e8s le tableau 9A du guide de l'IET sur site). Inscrivez clairement les r\u00e9sultats sur votre fiche d'essai.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0544d22 e-flex e-con-boxed e-con e-parent\" data-id=\"0544d22\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c222a1f elementor-widget elementor-widget-heading\" data-id=\"c222a1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test de continuit\u00e9 des circuits finaux de l'anneau\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38d903e elementor-widget elementor-widget-text-editor\" data-id=\"38d903e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Les circuits en anneau n\u00e9cessitent une v\u00e9rification suppl\u00e9mentaire pour confirmer non seulement que le circuit est complet, mais aussi qu'il n'y a pas de ruptures ou de croisements de conducteurs.<\/span><\/p><p><span style=\"font-weight: 400;\">Voici comment :<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3f96da elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"c3f96da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9connectez les deux extr\u00e9mit\u00e9s de l'anneau au niveau de l'unit\u00e9 consommateur (L1, N1, CPC1, et L2, N2, CPC2).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Mesurez s\u00e9par\u00e9ment la r\u00e9sistance de chaque conducteur d'un bout \u00e0 l'autre. <ul><li>Ligne (R\u2081)<\/li><li> Neutre (R\u2099)<\/li> <li> CPC (R\u2082)<\/li><\/ul><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Recouper la ligne et le neutre \u00e0 une extr\u00e9mit\u00e9, puis tester entre la ligne et le neutre sur plusieurs prises. Les relev\u00e9s doivent se situer dans une fourchette de 0,05 \u03a9, sans rupture ni croisement de paires.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">R\u00e9p\u00e9ter l'op\u00e9ration pour la ligne et le CPC afin d'obtenir les valeurs R\u2081 + R\u2082 pour chaque prise.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8dd9c14 elementor-widget elementor-widget-text-editor\" data-id=\"8dd9c14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">M\u00eames r\u00e9sultats = l'anneau est complet et \u00e9quilibr\u00e9. De grandes diff\u00e9rences = borne desserr\u00e9e ou mauvais \u00e9peron.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-79a6999 e-flex e-con-boxed e-con e-parent\" data-id=\"79a6999\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-45eebdc elementor-widget elementor-widget-heading\" data-id=\"45eebdc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test des interrupteurs, des fusibles et des \u00e9quipements fixes\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9f55696 elementor-widget elementor-widget-text-editor\" data-id=\"9f55696\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Les tests de continuit\u00e9 ne s'arr\u00eatent pas au c\u00e2blage. Vous v\u00e9rifierez \u00e9galement<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e3449f elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"7e3449f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Interrupteurs dont les contacts s'ouvrent et se ferment correctement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Fusibles et disjoncteurs dont les parcours internes sont continus lorsqu'ils sont en position de marche.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Continuit\u00e9 des points d'\u00e9clairage entre la phase commut\u00e9e, le neutre et le CPC.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3dc0e3b elementor-widget elementor-widget-text-editor\" data-id=\"3dc0e3b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Pour les interrupteurs, mesurer la continuit\u00e9 lorsque l'interrupteur est en position ON ; le circuit est ouvert lorsqu'il est en position OFF. Pour les \u00e9quipements fixes (tels que les thermoplongeurs ou les ventilateurs d'extraction), isoler et d\u00e9connecter une branche afin d'\u00e9viter les retours en arri\u00e8re pendant les essais.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-852cfe8 e-flex e-con-boxed e-con e-parent\" data-id=\"852cfe8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-528ed2f elementor-widget elementor-widget-heading\" data-id=\"528ed2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Erreurs courantes et comment les \u00e9viter\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b51590c elementor-widget elementor-widget-text-editor\" data-id=\"b51590c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">M\u00eame les \u00e9lectriciens exp\u00e9riment\u00e9s commettent des erreurs lors des tests de continuit\u00e9, souvent en raison de la pression du travail ou d'hypoth\u00e8ses.<\/span><\/p><p><span style=\"font-weight: 400;\">\u00c0 surveiller :<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e14453 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"7e14453\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La v\u00e9rification de l'isolement n'est pas effectu\u00e9e correctement. Il faut toujours utiliser un appareil de v\u00e9rification et non le testeur lui-m\u00eame.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Test par l'interm\u00e9diaire de neutres partag\u00e9s ou d'alimentations emprunt\u00e9es. Cela donne de faux r\u00e9sultats de continuit\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Ne pas enregistrer syst\u00e9matiquement les r\u00e9sultats. Chaque circuit devrait avoir une trace v\u00e9rifiable.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Ne pas effectuer d'inspection visuelle. L'isolation ou les terminaisons endommag\u00e9es sont souvent visibles avant le test.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-430d011 elementor-widget elementor-widget-text-editor\" data-id=\"430d011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Les tests professionnels sont synonymes de patience et de processus. La rapidit\u00e9 vient naturellement une fois que la m\u00e9thode est devenue une seconde nature.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2772f3a e-flex e-con-boxed e-con e-parent\" data-id=\"2772f3a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-80873a9 elementor-widget elementor-widget-heading\" data-id=\"80873a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Preuves, documentation et tra\u00e7abilit\u00e9\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb67c0d elementor-widget elementor-widget-text-editor\" data-id=\"cb67c0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Conform\u00e9ment \u00e0 la norme BS 7671, partie 6, les r\u00e9sultats des tests doivent \u00eatre document\u00e9s comme preuve de la v\u00e9rification. Pour les tests de continuit\u00e9, enregistrer :<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0757849 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"0757849\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La r\u00e9sistance mesur\u00e9e (en ohms).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">L'instrument d'essai utilis\u00e9 et les d\u00e9tails de l'\u00e9talonnage.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le nom ou les initiales du testeur et la date de la v\u00e9rification.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0814c58 elementor-widget elementor-widget-text-editor\" data-id=\"0814c58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Les r\u00e9sultats sont ensuite annex\u00e9s au certificat d'installation \u00e9lectrique (EIC) ou au certificat de travaux mineurs.<\/span><\/p><p><span style=\"font-weight: 400;\">Les journaux de test num\u00e9riques d'outils tels que Megger ou Fluke Connect peuvent simplifier cette t\u00e2che, en particulier lorsqu'un audit est n\u00e9cessaire.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-df1a2ff e-flex e-con-boxed e-con e-parent\" data-id=\"df1a2ff\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-74b1af5 elementor-widget elementor-widget-heading\" data-id=\"74b1af5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R\u00e9sultat final\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a866fc0 elementor-widget elementor-widget-text-editor\" data-id=\"a866fc0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Les tests de continuit\u00e9 prouvent que chaque joint, conducteur et CPC sous le pl\u00e2tre ou les goulottes fait son travail.\u00a0<\/span><\/p><p><span style=\"font-weight: 400;\">Lorsqu'il est bien fait, il prouve non seulement la conformit\u00e9 \u00e0 la norme BS 7671, mais aussi le savoir-faire et le devoir de diligence.<\/span><\/p><p><span style=\"font-weight: 400;\">Qu'il s'agisse de certifier un anneau domestique, d'inspecter un panneau triphas\u00e9 ou de remettre un am\u00e9nagement commercial, consid\u00e9rez le test de continuit\u00e9 comme votre signature sur le syst\u00e8me, une garantie qu'il est \u00e9lectriquement sain.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>When testing any electrical circuit, continuity is one of the most basic safety checks. It ensures every conductor, connection, and protective path is intact before any live power ever touches the system. But doing this test correctly isn\u2019t just about connecting a meter and waiting for a beep. It\u2019s about following BS 7671 and, just [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":10177,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_glsr_average":0,"_glsr_ranking":0,"_glsr_reviews":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-10166","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Continuity Testing On Circuits: Step-By-Step With GS38-Compliant Probes<\/title>\n<meta name=\"description\" content=\"Learn how to perform continuity testing step-by-step using GS38-compliant probes. Ensure safe, accurate circuit verification for UK electricians under BS 7671.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tradefoxapp.com\/fr\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Continuity Testing On Circuits: Step-By-Step With GS38-Compliant Probes\" \/>\n<meta property=\"og:description\" content=\"Learn how to perform continuity testing step-by-step using GS38-compliant probes. Ensure safe, accurate circuit verification for UK electricians under BS 7671.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tradefoxapp.com\/fr\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/\" \/>\n<meta property=\"og:site_name\" content=\"Tradefox | Construction Training Online\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61561067514381\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-23T04:57:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-16T05:21:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"825\" \/>\n\t<meta property=\"og:image:height\" content=\"550\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tradefoxapp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tradefox_app\" \/>\n<meta name=\"twitter:site\" content=\"@Tradefox_app\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tradefoxapp\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/\"},\"author\":{\"name\":\"Tradefoxapp\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#\\\/schema\\\/person\\\/cad3ebca9b0c18ad17cdf9222b9e4d06\"},\"headline\":\"Continuity Testing On Circuits: Step-By-Step With GS38-Compliant Probes\",\"datePublished\":\"2025-10-23T04:57:20+00:00\",\"dateModified\":\"2025-12-16T05:21:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/\"},\"wordCount\":1063,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg\",\"articleSection\":[\"Electrical\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/\",\"name\":\"Continuity Testing On Circuits: Step-By-Step With GS38-Compliant Probes\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg\",\"datePublished\":\"2025-10-23T04:57:20+00:00\",\"dateModified\":\"2025-12-16T05:21:35+00:00\",\"description\":\"Learn how to perform continuity testing step-by-step using GS38-compliant probes. Ensure safe, accurate circuit verification for UK electricians under BS 7671.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg\",\"contentUrl\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg\",\"width\":825,\"height\":550},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/tradefoxapp.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Continuity Testing On Circuits: Step-By-Step With GS38-Compliant Probes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#website\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/\",\"name\":\"Tradefox | Construction Training Online\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tradefoxapp.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#organization\",\"name\":\"Tradefox | Construction Training Online\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/logo-transperent.png\",\"contentUrl\":\"https:\\\/\\\/tradefoxapp.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/logo-transperent.png\",\"width\":1024,\"height\":208,\"caption\":\"Tradefox | Construction Training Online\"},\"image\":{\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=61561067514381\",\"https:\\\/\\\/x.com\\\/Tradefox_app\",\"https:\\\/\\\/www.instagram.com\\\/tradefoxapp\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/tradefox-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tradefoxapp.com\\\/#\\\/schema\\\/person\\\/cad3ebca9b0c18ad17cdf9222b9e4d06\",\"name\":\"Tradefoxapp\",\"sameAs\":[\"https:\\\/\\\/tradefoxapp.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Test de continuit\u00e9 sur les circuits : Pas \u00e0 pas avec les sondes conformes \u00e0 la norme GS38","description":"Learn how to perform continuity testing step-by-step using GS38-compliant probes. Ensure safe, accurate circuit verification for UK electricians under BS 7671.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tradefoxapp.com\/fr\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/","og_locale":"fr_FR","og_type":"article","og_title":"Continuity Testing On Circuits: Step-By-Step With GS38-Compliant Probes","og_description":"Learn how to perform continuity testing step-by-step using GS38-compliant probes. Ensure safe, accurate circuit verification for UK electricians under BS 7671.","og_url":"https:\/\/tradefoxapp.com\/fr\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/","og_site_name":"Tradefox | Construction Training Online","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61561067514381","article_published_time":"2025-10-23T04:57:20+00:00","article_modified_time":"2025-12-16T05:21:35+00:00","og_image":[{"width":825,"height":550,"url":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg","type":"image\/jpeg"}],"author":"Tradefoxapp","twitter_card":"summary_large_image","twitter_creator":"@Tradefox_app","twitter_site":"@Tradefox_app","twitter_misc":{"\u00c9crit par":"Tradefoxapp","Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/#article","isPartOf":{"@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/"},"author":{"name":"Tradefoxapp","@id":"https:\/\/tradefoxapp.com\/#\/schema\/person\/cad3ebca9b0c18ad17cdf9222b9e4d06"},"headline":"Continuity Testing On Circuits: Step-By-Step With GS38-Compliant Probes","datePublished":"2025-10-23T04:57:20+00:00","dateModified":"2025-12-16T05:21:35+00:00","mainEntityOfPage":{"@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/"},"wordCount":1063,"commentCount":0,"publisher":{"@id":"https:\/\/tradefoxapp.com\/#organization"},"image":{"@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/#primaryimage"},"thumbnailUrl":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg","articleSection":["Electrical"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/","url":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/","name":"Test de continuit\u00e9 sur les circuits : Pas \u00e0 pas avec les sondes conformes \u00e0 la norme GS38","isPartOf":{"@id":"https:\/\/tradefoxapp.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/#primaryimage"},"image":{"@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/#primaryimage"},"thumbnailUrl":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg","datePublished":"2025-10-23T04:57:20+00:00","dateModified":"2025-12-16T05:21:35+00:00","description":"Learn how to perform continuity testing step-by-step using GS38-compliant probes. Ensure safe, accurate circuit verification for UK electricians under BS 7671.","breadcrumb":{"@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/#primaryimage","url":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg","contentUrl":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2025\/10\/electrician-working-near-board-with-wires-installation-connection-electrics.jpg","width":825,"height":550},{"@type":"BreadcrumbList","@id":"https:\/\/tradefoxapp.com\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/tradefoxapp.com\/"},{"@type":"ListItem","position":2,"name":"Continuity Testing On Circuits: Step-By-Step With GS38-Compliant Probes"}]},{"@type":"WebSite","@id":"https:\/\/tradefoxapp.com\/#website","url":"https:\/\/tradefoxapp.com\/","name":"Tradefox | Formation en construction en ligne","description":"","publisher":{"@id":"https:\/\/tradefoxapp.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tradefoxapp.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/tradefoxapp.com\/#organization","name":"Tradefox | Formation en construction en ligne","url":"https:\/\/tradefoxapp.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tradefoxapp.com\/#\/schema\/logo\/image\/","url":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/03\/logo-transperent.png","contentUrl":"https:\/\/tradefoxapp.com\/wp-content\/uploads\/2026\/03\/logo-transperent.png","width":1024,"height":208,"caption":"Tradefox | Construction Training Online"},"image":{"@id":"https:\/\/tradefoxapp.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=61561067514381","https:\/\/x.com\/Tradefox_app","https:\/\/www.instagram.com\/tradefoxapp\/","https:\/\/www.linkedin.com\/company\/tradefox-ltd\/"]},{"@type":"Person","@id":"https:\/\/tradefoxapp.com\/#\/schema\/person\/cad3ebca9b0c18ad17cdf9222b9e4d06","name":"Tradefoxapp","sameAs":["https:\/\/tradefoxapp.com"]}]}},"_links":{"self":[{"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/posts\/10166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/comments?post=10166"}],"version-history":[{"count":18,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/posts\/10166\/revisions"}],"predecessor-version":[{"id":11379,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/posts\/10166\/revisions\/11379"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/media\/10177"}],"wp:attachment":[{"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/media?parent=10166"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/categories?post=10166"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tradefoxapp.com\/fr\/wp-json\/wp\/v2\/tags?post=10166"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}